Abstract
This study was performed to investigate the changes in meat quality characteristics of the sous vide cooked chicken breast during refrigerated storage at 4℃ for 14 d between before and after sous-vide cooking. Cooking loss and shear force were significantly increased, whereas expressible drip was significantly decreased along with reduction in the water holding capacity in both of two groups. Redness of meat juice was significantly (p<0.05) increased during storage, and considerably increased in the refrigerated samples after sous-vide cooked at the 7 to 10 d. The thiobarbituric acid reactive substances (TBARS) was significantly increased and was higher in the refrigerator stored chicken breast samples after sous-vide cooking. The volatile basic nitrogen (VBN) value was significantly increased in both groups, but the VBN value of the stored raw meat sample before sous-vide cooking was increased at an early storage, while the VBN value of the stored sample after sous-vide cooking was increased gradually in this study. Total viable counts and coliform counts were significantly decreased during storage, and coliforms were not detected after 7 d of storage in both groups. Salmonella spp. was not detected during the whole studied period. The outcome of this research can provide preliminary data that could be used to apply for further study of chicken breast using sous-vide cooking method that could be attractive to consumers.Entities:
Keywords: chicken breast; meat characteristic; molecular gastronomy; poultry meat; sous vide
Year: 2015 PMID: 26877635 PMCID: PMC4726955 DOI: 10.5851/kosfa.2015.35.6.757
Source DB: PubMed Journal: Korean J Food Sci Anim Resour ISSN: 1225-8563 Impact factor: 2.622
Changes in the moisture and crude protein contents in raw meat storage samples (R) and Sous-Vide meat storage samples (S) at 4℃
| Storage period (d) | Moisture content | Crude protein content | ||
|---|---|---|---|---|
| R group | S group | R group | S group | |
| 0 | 71.43±1.778NS | 71.43±1.778NS | 26.69±0.317NS | 26.69±0.317NS |
| 3 | 71.16±1.593 | 70.81±0.582 | 26.73±1.256 | 28.56±1.272 |
| 5 | 72.59±1.340 | 72.35±0.483 | 27.03±1.076 | 26.77±0.449 |
| 7 | 73.84±1.149 | 72.18±0.357 | 26.32±0.631 | 27.66±1.006 |
| 10 | 70.36±0.702 | 71.71±0.745 | 27.90±0.953 | 27.42±0.595 |
| 14 | 72.23±1.635 | 71.80±0.217 | 28.38±1.001 | 26.51±0.563 |
| SEM | 1.15 | 0.70 | 0.76 | 0.63 |
| 0.116 | 0.355 | 0.119 | 0.055 | |
All values are presented as means±SD (n=15).
NSNot statistically significant.
Changes in cooking loss, shear force, and expressible drip in raw chicken breast storage samples (R) and Sous-Vide storage samples (S) stored at 4℃ for 14 d
| Storage period (d) | Cooking loss (%) | Shear force (kg/§2) | Expressible drip (%) | |||
|---|---|---|---|---|---|---|
| R group | S group | R group | S group | R group | S group | |
| 0 | 11.50±1.460a | 12.41±1.472a | 1.01±0.042a | 1.01±0.042a | 50.26±4.101NS | 51.06±2.718b |
| 3 | 13.84±2.410ab | 15.06±1.073ab | 1.56±0.046b* | 1.19±0.106b | 45.87±4.944 | 46.48±2.671ab |
| 5 | 15.55±1.217abc* | 19.48±1.634bc | 1.66±0.017bc** | 1.30±0.052bc | 43.19±0.854 | 44.79±1.079a |
| 7 | 20.32±1.521c | 17.06±0.554bc | 1.87±0.100c** | 1.37±0.059c | 43.23±3.672 | 42.62±1.319a |
| 10 | 20.01±2.635c | 19.88±1.083c | 2.68±0.170d* | 2.22±0.067d | 45.09±0.416 | 43.16±1.074a |
| 14 | 17.57 ±2.843bc | 17.21±1.537c | 2.64±0.018d*** | 2.24±0.020d | 46.20±1.150 | 43.76±1.486a |
| SEM | 1.725 | 1.045 | 0.069 | 0.052 | 2.516 | 1.520 |
| 0.001 | <0.001 | <0.001 | <0.001 | 0.131 | 0.001 | |
All values are presented as means±SD (n=15).
a-dMean values with different superscripts within the same column differ significantly (p<0.05).
*,**,***Mean values with an asterisk mark within a row during the same storage period differ significantly (*p<0.05, **p<0.01, ***p<0.001).
Fig. 1.The pink color of the drip in raw-meat storage samples (R) and Sous-Vide cooked storage samples (S) stored at 4℃ was assessed using a spectrophotometer at 550 nm. a-fMeans sharing different letters during the each storage period are significantly different (p<0.05). SEM: R=0.006, S=0.005, p-value: R<0.001, S<0.001.
Changes in 2-Thiobarbituric acid reactive substances (TBARS) and volatile basic nitrogen (VBN) values in raw meat samples (R) and Sous-Vide meat samples (S) during storage at 4℃
| Storage period (d) | TBARS (mg/kg) | VBN (mg%) | ||
|---|---|---|---|---|
| R group | S group | R group | S group | |
| 0 | 1.30±0.24a | 1.14±0.39a | 19.42±1.71a | 19.04±1.12a |
| 3 | 1.25±0.16a* | 1.72±0.16a | 22.96±0.56b | 22.97±0.56b |
| 5 | 1.56±0.16a | 1.77±0.48a | 25.19±0.56bc** | 22.95±0.56b |
| 7 | 1.09±0.16a | 1.92±0.39ab | 25.40±1.41bc | 23.52±0.56b |
| 10 | 1.66±0.45a* | 2.81±0.16bc | 26.50±0.65c** | 23.31±0.85b |
| 14 | 2.55±0.09b* | 3.17±0.24c | 27.99±1.12c | 26.84±1.12c |
| SEM | 0.195 | 0.267 | 0.895 | 0.681 |
| <0.001 | <0.001 | <0.001 | <0.001 | |
All values are presented as means±SD (n=15).
NSNot statistically significant.
a-cMean values with different superscripts within the same column differ significantly (p<0.05).
*,**Mean values with an asterisk mark within a row during the same storage period differ significantly (*p<0.05, **p<0.01).
The total viable counts (TVC), coliform counts, and Salmonella spp. in raw meat storage samples (R) and Sous-Vide meat storage samples (S) stored at 4℃ (Log10 CFU/g)
| Storage period (d) | TVC | Coliform counts | ||||
|---|---|---|---|---|---|---|
| R group | S group | R group | S group | R group | S group | |
| 0 | 4.38±0.11c | 4.38±0.11d | 2.29±0.23NS | 2.61±0.10b | ND | ND |
| 3 | 4.18±0.07c** | 3.83±0.08c | 2.39±0.08** | 1.26±0.24a | ND | ND |
| 5 | 4.22±0.14c** | 2.84±0.21a | 2.31±0.11** | 1.26±0.24a | ND | ND |
| 7 | 2.26±0.24b** | 3.52±0.20bc | ND | ND | ND | ND |
| 10 | 1.93±0.01ab** | 3.16±0.15ab | ND | ND | ND | ND |
| 14 | 1.63±0.11a** | 3.01±0.21a | ND | ND | ND | ND |
| SEM | 0.109 | 0.137 | 0.130 | 0.170 | - | - |
| <0.001 | <0.001 | 0.695 | <0.001 | - | - | |
All values are presented as means±SD (n=15).
ND: Not detected.
a-dMean values with different superscripts within the same column differ significantly (p<0.05).
*,**Mean values with an asterisk mark within a row during the same storage period differ significantly (*p<0.05, **p<0.01).