Immediate Single-Tooth Implant Placement in Bony Defects in the Esthetic Zone: A 1-Year Randomized Controlled Trial.

Kirsten W Slagter1, Henny J A Meijer1,2, Nicolaas A Bakker3, Arjan Vissink1, Gerry M Raghoebar1.   

Abstract

BACKGROUND: This study aims to assess, with regard to marginal bone level (MBL), whether the outcome of immediate implant placement in bony defects in the esthetic zone was non-inferior to delayed implant placement after 1 year.
METHODS: Forty patients with a failing tooth in the esthetic zone and a labial bony defect of ≥5 mm after removal of a tooth were randomly assigned for immediate (n = 20) or delayed (n = 20) implant placement. Second-stage surgery and provisionalization occurred after 3 months of healing. Follow-up was at 1 month and 1 year after definitive crown placement. The study was powered to detect a difference in MBL of >0.9 mm. Buccal bone thickness, soft tissue peri-implant parameters, esthetic indices, and patient satisfaction were also assessed.
RESULTS: One year after definitive crown placement, MBL loss was 0.56 ± 0.39 mm mesially and 0.74 ± 0.51 mm distally for the immediate placement group and 0.51 ± 0.43 mesially and 0.54 ± 0.45 distally mm for the delayed placement group, respectively (not significant). Regarding differences in means, non-inferiority was observed after 1 year (difference in mean for immediate versus delayed: mesially 0.04 mm [95% confidence interval (CI) = -0.22 to 0.30 mm, P = 0.40]; distally 0.21 mm [95% CI = -0.10 to 0.51 mm, P = 0.58]). No significant differences in the other outcome variables were observed.
CONCLUSIONS: Immediate implant placement with delayed provisionalization was non-inferior to delayed implant placement with delayed provisionalization in labial bony defects of ≥5 mm regarding change in MBL. Although not powered for other outcome variables, no clinically relevant differences were observed in these variables.

Entities:  

Keywords:  Dental implantation; dental impants; dental impants, single tooth; dental implantation, endosseous; dental restoration, permanent; esthetics, dental

Mesh:

Year:  2016        PMID: 26876349     DOI: 10.1902/jop.2016.150417

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  7 in total

Review 1.  Clinical and esthetic outcomes of immediate implant placement compared to alveolar ridge preservation: a systematic review and meta-analysis.

Authors:  Santiago Mareque; Pablo Castelo-Baz; Joaquín López-Malla; Juan Blanco; José Nart; Cristina Vallés
Journal:  Clin Oral Investig       Date:  2021-06-07       Impact factor: 3.573

2.  Effect of osseodensification on the increase in ridge thickness and the prevention of buccal peri-implant defects: an in vitro randomized split mouth pilot study.

Authors:  Fausto Frizzera; Rubens Spin-Neto; Victor Padilha; Nicolas Nicchio; Bruna Ghiraldini; Fábio Bezerra; Elcio Marcantonio
Journal:  BMC Oral Health       Date:  2022-06-13       Impact factor: 3.747

Review 3.  Comparing success of immediate versus delay loading of implants in fresh sockets: a systematic review and meta-analysis.

Authors:  Ebrahim Eini; Hojatollah Yousefimanesh; Alireza Hashemi Ashtiani; Amal Saki-Malehi; Amin Olapour; Fakher Rahim
Journal:  Oral Maxillofac Surg       Date:  2021-07-12

4.  Buccal bone thickness at dental implants in the maxillary anterior region with large bony defects at time of immediate implant placement: A 1-year cohort study.

Authors:  Henny J A Meijer; Kirsten W Slagter; Arjan Vissink; Gerry M Raghoebar
Journal:  Clin Implant Dent Relat Res       Date:  2018-12-11       Impact factor: 3.932

5.  Alveolar ridge preservation in defect sockets in the maxillary aesthetic zone followed by single-tooth bone level tapered implants with immediate provisionalization: a 1-year prospective case series.

Authors:  Caroliene M Meijndert; Gerry M Raghoebar; Arjan Vissink; Henny J A Meijer
Journal:  Int J Implant Dent       Date:  2021-02-19

6.  Esthetic results of immediate implant placement in extraction sockets with intact versus deficient walls.

Authors:  Kang-Shuo Hu; Hua Li; Yu-Kang Tu; Shih-Jung Lin
Journal:  J Dent Sci       Date:  2020-07-14       Impact factor: 2.080

Review 7.  The effect of implant-abutment connections on peri-implant bone levels around single implants in the aesthetic zone: A systematic review and a meta-analysis.

Authors:  Caroliene M Meijndert; Gerry M Raghoebar; Arjan Vissink; Konstantina Delli; Henny J A Meijer
Journal:  Clin Exp Dent Res       Date:  2021-08-21
  7 in total