Literature DB >> 26875271

[CLINICAL APPLICATION OF INDIVIDUALIZED REFERENCE MODEL OF SAGITTAL CURVES AND NAVIGATION TEMPLATES OF PEDICLE SCREW BY THREE-DIMENSIONAL PRINTING TECHNIQUE FOR THORACOLUMBAR FRACTURE WITH DISLOCATION].

Chao Wu, Lun Tan, Xu Lin, Haigang Hu.   

Abstract

OBJECTIVE: To evaluate the clinical significance of individualized reference model of sagittal curves and navigation templates of pedicle screw by three-dimensional printing technique for thoracolumbar fracture with dislocation.
METHODS: Between February 2011 and November 2013, 42 patients with thoracolumbar fracture and dislocation undergoing pedicle screw fixation were divided into 2 groups: traditional pedicle screw internal fixation by fluoroscopy assistant was used in 24 cases (control group), and individualized reference model of sagittal curves and navigation templates of pedicle screw were used in 18 cases (trial group). There was no significant difference in gender, age, injury causes, segment, degree of dislocation, and Frankel classification between 2 groups (P > 0.05). The operation time, intraoperative blood loss, perspective times, and dislocation rate, sagittal angle recovery rate at different time were compared. The success rate of pedicle screw insertion, sagittal screw angle, and Frankel classification were compared. The angle between sagittal screws, difference of screw entry point at horizontal position, and difference of screw inclined angle were compared.
RESULTS: The operating time, intraoperative blood loss, and perspective times in trial group were significantly lower than those in control groups (P < 0.05). All the patients were followed up 12-40 months (mean, 22 months). The dislocation rate at immediate after operation and last follow-up were significantly improved when compared with preoperative value in 2 groups (P < 0.05). At immediate after operation and last follow-up, the dislocation rate and sagittal angle recover rate in trial group were significantly better than those in control group (P < 0.05). There were significant differences in the one-time success rate, final success rate of pedicle screw insertion, and saggital screw angle between 2 groups (χ2 = 9.38, P = 0.00; χ2 = 10.95, P = 0.00; χ2 = 13.43, P = 0.00). The angle between sagittal screws, difference of screw entry point at horizontal position, and difference of screw inclined angle in trail group were significantly less than those in control group (P < 0.05). There was significant difference in the Frankel classification between 2 groups at last follow-up (Z = -1.99, P = 0.04).
CONCLUSION: The application of individualized reference model of sagittal curves and navigation templates of pedicle screw by three-dimensional printing technique for thoracolumbar fracture with dislocation has the advantages of shorter operation time, less intraoperative blood loss, better recovery of thoracolumbar dislocation, and better Frankel classification.

Entities:  

Mesh:

Year:  2015        PMID: 26875271

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  3 in total

1.  [Clinical application of three-dimensional printing technique combined with thoracic pedicle screw track detector in thoracic pedicle screw placement].

Authors:  Hu Nie; Guoqi Niu; Gong Zhou; Tao Liu; Hui Chen; Chao Li
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-05-15

Review 2.  A Review of Current Clinical Applications of Three-Dimensional Printing in Spine Surgery.

Authors:  Woojin Cho; Alan Varkey Job; Jing Chen; Jung Hwan Baek
Journal:  Asian Spine J       Date:  2018-02-07

3.  Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis.

Authors:  Chengqiang Yu; Yufu Ou; Chengxin Xie; Yu Zhang; Jianxun Wei; Xiaoping Mu
Journal:  J Orthop Surg Res       Date:  2020-01-03       Impact factor: 2.359