Do accelerometers mounted on the back provide a good estimate of impact loads in jumping and landing tasks?

Chantal Simons1, Elizabeth J Bradshaw1.   

Abstract

Artistic gymnasts are frequently exposed to both low- and high-magnitude loads through impacts with the apparatus. These impact loads are thought to be associated with the high injury rates observed in gymnastics. Due to the variable apparatus and surfaces in gymnastics, impact loads during training are difficult to quantify. This study aimed to use triaxial accelerometers mounted on the back to assess impact loading during jumping and landing tasks. Twelve participants were fitted with an accelerometer on their upper and lower back, before performing a continuous hopping task, as well as drop landings and rebound jumps from various heights (37.5, 57.5, and 77.5 cm) onto a force platform. Peak resultant acceleration (PRA) was low-pass filtered with four cut-off frequencies (8, 15, 20, and 50 Hz). Filtering of PRA with the 20 Hz cut-off frequency showed the highest correlations between ground reaction force (GRF) and PRA. PRA recorded at the upper back, filtered with a 20 Hz cut-off frequency, appears to provide a good estimate of impact loading for continuous hopping and rebound jumps, but less so for drop landings since correlations between GRF and PRA were only significant when landing from 57.5 cm.

Entities:  

Keywords:  Biomechanics; acceleration; filter; ground reaction force; sport

Mesh:

Year:  2016        PMID: 26873303     DOI: 10.1080/14763141.2015.1123765

Source DB:  PubMed          Journal:  Sports Biomech        ISSN: 1476-3141            Impact factor:   2.832


  6 in total

Review 1.  The Use of Wearable Sensors for Preventing, Assessing, and Informing Recovery from Sport-Related Musculoskeletal Injuries: A Systematic Scoping Review.

Authors:  Ezio Preatoni; Elena Bergamini; Silvia Fantozzi; Lucie I Giraud; Amaranta S Orejel Bustos; Giuseppe Vannozzi; Valentina Camomilla
Journal:  Sensors (Basel)       Date:  2022-04-22       Impact factor: 3.847

2.  Accelerometer-based prediction of skeletal mechanical loading during walking in normal weight to severely obese subjects.

Authors:  L Veras; F Diniz-Sousa; G Boppre; V Devezas; H Santos-Sousa; J Preto; J P Vilas-Boas; L Machado; J Oliveira; H Fonseca
Journal:  Osteoporos Int       Date:  2020-01-21       Impact factor: 4.507

3.  High-Impact Details of Play and Movements in Female Basketball Game.

Authors:  Yasuharu Nagano; Shogo Sasaki; Yui Shimada; Takeshi Koyama; Hiroshi Ichikawa
Journal:  Sports Med Int Open       Date:  2021-02-03

4.  Accelerometer-based prediction of ground reaction force in head-out water exercise with different exercise intensity countermovement jump.

Authors:  Kuei-Yu Chien; Wei-Gang Chang; Wan-Chin Chen; Rong-Jun Liou
Journal:  BMC Sports Sci Med Rehabil       Date:  2022-01-03

Review 5.  A Focused Review on the Flexible Wearable Sensors for Sports: From Kinematics to Physiologies.

Authors:  Lei Liu; Xuefeng Zhang
Journal:  Micromachines (Basel)       Date:  2022-08-20       Impact factor: 3.523

6.  Application of an Accelerometric System for Determination of Stiffness during a Hopping Task.

Authors:  Artur Struzik; Jerzy Zawadzki; Andrzej Rokita; Bogdan Pietraszewski
Journal:  Appl Bionics Biomech       Date:  2020-05-21       Impact factor: 1.781

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.