New insights into rotating frame relaxation at high field.

John T Spear1, John C Gore1.   

Abstract

Measurements of spin-lock relaxation rates in the rotating frame (R1ρ ) at high magnetic fields afford the ability to probe not only relatively slow molecular motions, but also other dynamic processes, such as chemical exchange and diffusion. In particular, measurements of the variation (or dispersion) of R1ρ with locking field allow the derivation of quantitative parameters that describe these processes. Measurements in deuterated solutions demonstrate the manner and degree to which exchange dominates relaxation at high fields (4.7 T, 7 T) in simple solutions, whereas temperature and pH are shown to be very influential factors affecting the rates of proton exchange. Simulations and experiments show that multiple exchanging pools of protons in realistic tissues can be assumed to behave independently of each other. R1ρ measurements can be combined to derive an exchange rate contrast (ERC) that produces images whose intensities emphasize protons with specific exchange rates rather than chemical shifts. In addition, water diffusion in the presence of intrinsic susceptibility gradients may produce significant effects on R1ρ dispersions at high fields. The exchange and diffusion effects act independently of each other, as confirmed by simulation and experimentally in studies of red blood cells at different levels of oxygenation. Collectively, R1ρ measurements provide an ability to quantify exchange processes, to provide images that depict protons with specific exchange rates and to describe the microstructure of tissues containing magnetic inhomogeneities. As such, they complement traditional T1 or T2 measurements and provide additional insights from measurements of R1ρ at a single locking field.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  T1ρ; T1ρ dispersion; chemical exchange; diffusion; spin-locking; susceptibility

Mesh:

Substances:

Year:  2016        PMID: 26866422      PMCID: PMC6935321          DOI: 10.1002/nbm.3490

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  58 in total

1.  Correlation functions for inhomogeneous magnetic field in random media with application to a dense random pack of spheres.

Authors:  B Audoly; P N Sen; S Ryu; Y-Q Song
Journal:  J Magn Reson       Date:  2003-09       Impact factor: 2.229

2.  Effects of intracellular pH, blood, and tissue oxygen tension on T1rho relaxation in rat brain.

Authors:  Mikko I Kettunen; Olli H J Gröhn; M Johanna Silvennoinen; Markku Penttonen; Risto A Kauppinen
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

3.  In vivo measurement of T1rho dispersion in the human brain at 1.5 tesla.

Authors:  Arijitt Borthakur; Andrew J Wheaton; Alexander J Gougoutas; Sarma V S Akella; Ravinder R Regatte; Sridhar R Charagundla; Ravinder Reddy
Journal:  J Magn Reson Imaging       Date:  2004-04       Impact factor: 4.813

4.  T1rho contrast in functional magnetic resonance imaging.

Authors:  Justin Hulvershorn; Arijitt Borthakur; Luke Bloy; Eugene E Gualtieri; Ravinder Reddy; John S Leigh; Mark A Elliott
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

5.  The influence of chemical and diffusive exchange on water proton transverse relaxation in plant tissues.

Authors:  B P Hills; S L Duce
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

6.  Dispersion of relaxation rates in the rotating frame under the action of spin-locking pulses and diffusion in inhomogeneous magnetic fields.

Authors:  John T Spear; Zhongliang Zu; John C Gore
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

7.  Functional MRI using spin lock editing preparation pulses.

Authors:  Swati Rane; John T Spear; Zhongliang Zu; Manus J Donahue; John C Gore
Journal:  Magn Reson Imaging       Date:  2014-04-13       Impact factor: 2.546

8.  Transfer functions for describing ultrasound system performance.

Authors:  J C Gore; S Leeman
Journal:  Phys Med Biol       Date:  1979-01       Impact factor: 3.609

9.  Spin-lock techniques and CPMG imaging sequences: a critical appraisal of T1p contrast at 0.15 T.

Authors:  R V Mulkern; S Patz; M Brooks; D C Metcalf; F A Jolesz
Journal:  Magn Reson Imaging       Date:  1989 Sep-Oct       Impact factor: 2.546

10.  Imaging brain deoxyglucose uptake and metabolism by glucoCEST MRI.

Authors:  Fatima A Nasrallah; Guilhem Pagès; Philip W Kuchel; Xavier Golay; Kai-Hsiang Chuang
Journal:  J Cereb Blood Flow Metab       Date:  2013-05-15       Impact factor: 6.200

View more
  10 in total

1.  MRI and biomechanics multidimensional data analysis reveals R2 -R as an early predictor of cartilage lesion progression in knee osteoarthritis.

Authors:  Valentina Pedoia; Jenny Haefeli; Kazuhito Morioka; Hsiang-Ling Teng; Lorenzo Nardo; Richard B Souza; Adam R Ferguson; Sharmila Majumdar
Journal:  J Magn Reson Imaging       Date:  2017-05-04       Impact factor: 4.813

2.  Spin-lock imaging of 3-o-methyl-D glucose (3oMG) in brain tumors.

Authors:  Zhongliang Zu; Xiaoyu Jiang; Junzhong Xu; John C Gore
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

3.  Spin-lock imaging of early tissue pH changes in ischemic rat brain.

Authors:  Zhongliang Zu; Aqeela Afzal; Hua Li; Jingping Xie; John C Gore
Journal:  NMR Biomed       Date:  2018-02-09       Impact factor: 4.044

4.  An order parameter without magic angle effect (OPTIMA) derived from R 1 ρ dispersion in ordered tissue.

Authors:  Yuxi Pang
Journal:  Magn Reson Med       Date:  2019-11-05       Impact factor: 4.668

5.  Spin-lock imaging of exogenous exchange-based contrast agents to assess tissue pH.

Authors:  Zhongliang Zu; Hua Li; Xiaoyu Jiang; John C Gore
Journal:  Magn Reson Med       Date:  2017-03-20       Impact factor: 4.668

6.  "Molecular" MR imaging at high fields.

Authors:  John C Gore; Zhongliang Zu; Ping Wang; Hua Li; Junzhong Xu; Richard Dortch; Daniel F Gochberg
Journal:  Magn Reson Imaging       Date:  2016-12-08       Impact factor: 2.546

7.  Composite metric R2  - R (1/T2  - 1/T ) as a potential MR imaging biomarker associated with changes in pain after ACL reconstruction: A six-month follow-up.

Authors:  Colin Russell; Valentina Pedoia; Sharmila Majumdar
Journal:  J Orthop Res       Date:  2016-09-16       Impact factor: 3.494

8.  R1ρ sensitivity to pH and other compounds at clinically accessible spin-lock fields in the presence of proteins.

Authors:  Nana Owusu; Casey P Johnson; William Kearney; Dan Thedens; John Wemmie; Vincent A Magnotta
Journal:  NMR Biomed       Date:  2019-11-19       Impact factor: 4.044

9.  Spin-lock imaging of intrinsic susceptibility gradients in tumors.

Authors:  Zhongliang Zu; Vaibhav Janve; John C Gore
Journal:  Magn Reson Med       Date:  2019-12-27       Impact factor: 4.668

Review 10.  Proton Exchange Magnetic Resonance Imaging: Current and Future Applications in Psychiatric Research.

Authors:  Joseph J Shaffer; Merry Mani; Samantha L Schmitz; Jia Xu; Nana Owusu; Dee Wu; Vincent A Magnotta; John A Wemmie
Journal:  Front Psychiatry       Date:  2020-09-24       Impact factor: 4.157

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.