Performance of High Flow Rate Personal Respirable Samplers When Challenged with Mineral Aerosols of Different Particle Size Distributions.

Peter Stacey1, Andrew Thorpe2, Alan Echt3.   

Abstract

It is thought that the performance of respirable samplers may vary when exposed to dust aerosols with different particle sizes and wind speeds. This study investigated the performance of the GK 4.16 (RASCAL), GK 2.69, PPI 8, and FSP 10, high flow rate personal samplers when exposed to aerosols of mineral dust in a wind tunnel at two different wind speeds (1 and 2 m s(-1)) and orientations (towards and side-on to the source of emission). The mass median aerodynamic diameter of four aerosolized test dusts ranged from 8 to 25 µm with geometric standard deviations from 1.6 to 2 µm. The performance of each sampler type was compared with that of the SIMPEDS (Higgins-Dewell design) sampler. There was slight evidence to suggest that the performance of the FSP 10 is affected by the direction of the inlet relative to the air flow, although this was not significant when most respirable dust concentrations were compared, possibly due to the variability of paired dust concentration results. The GK 2.69, RASCAL, and PPI 8 samplers had similar performances, although the results when side-on to the emission source were generally slightly lower than the SIMPEDS. Despite slight differences between respirable dust concentrations the respirable crystalline silica values were not significantly different from the SIMPEDS. The GK family of cyclones obtained most precise results and more closely matched the SIMPEDS. A comparison with dust concentration results from previous calm air chamber studies (where wind speeds were < 0.4 m s(-1)) found that the relative performance between samplers was similar to those observed in this work indicating consistent performance relative to the SIMPEDS in both calm and moving air. © Crown copyright 2016.

Entities:  

Keywords:  X-ray diffraction.; aerosol sampling; cyclone; high flow rate; particle size; personal impactor sampler; respirable dust; silica

Mesh:

Substances:

Year:  2016        PMID: 26865560      PMCID: PMC4815938          DOI: 10.1093/annhyg/mev097

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  5 in total

1.  Quartz measurement in coal dust with high-flow rate samplers: laboratory study.

Authors:  Taekhee Lee; Eun Gyung Lee; Seung Won Kim; William P Chisholm; Michael Kashon; Martin Harper
Journal:  Ann Occup Hyg       Date:  2011-12-19

2.  A higher-flow rate cyclone for determination of respirable dust.

Authors:  J R Cossey; N P Vaughan
Journal:  Ann Occup Hyg       Date:  1987

3.  Performance of high flow rate samplers for respirable particle collection.

Authors:  Taekhee Lee; Seung Won Kim; William P Chisholm; James Slaven; Martin Harper
Journal:  Ann Occup Hyg       Date:  2010-07-21

4.  Evaluation of pump pulsation in respirable size-selective sampling: part II. Changes in sampling efficiency.

Authors:  Eun Gyung Lee; Taekhee Lee; Seung Won Kim; Larry Lee; Michael M Flemmer; Martin Harper
Journal:  Ann Occup Hyg       Date:  2013-09-24

5.  Collection efficiencies of high flow rate personal respirable samplers when measuring Arizona road dust and analysis of quartz by x-ray diffraction.

Authors:  Peter Stacey; Taekhee Lee; Andrew Thorpe; Paul Roberts; Gillian Frost; Martin Harper
Journal:  Ann Occup Hyg       Date:  2014-01-27
  5 in total
  1 in total

1.  Laboratory comparison of new high flow rate respirable size-selective sampler.

Authors:  Taekhee Lee; Andrew Thorpe; Emanuele Cauda; Leah Tipton; Wayne T Sanderson; Alan Echt
Journal:  J Occup Environ Hyg       Date:  2018-10       Impact factor: 2.155

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.