Literature DB >> 26863938

Washout rate in rat brain irradiated by a (11)C beam after acetazolamide loading using a small single-ring OpenPET prototype.

Yoshiyuki Hirano, Hiroyuki Takuwa, Eiji Yoshida, Fumihiko Nishikido, Yasunori Nakajima, Hidekatsu Wakizaka, Taiga Yamaya.   

Abstract

In dose verification techniques of particle therapies based on in-beam positron emission tomography (PET), the causes of washout of positron emitters by physiological effects should be clarified to correct washout for accurate verification. As well, the quantitative washout rate has a potential usefulness as a diagnostic index which should be explored. Therefore, we measured washout rates of rat brain after vasodilator acetazolamide loading to investigate the possible effects of blood flow on washout. Six rat brains were irradiated by a radioisotope (11)C beam and time activity curves on the whole brains were obtained with a small single-ring OpenPET prototype. Then, washout rates were calculated with the Mizuno model, where two washout rates (k 2m and k 2s ) were assumed, and a two-compartment model including efflux from tissue to blood (k 2) and influx (k 3) and efflux (k 4) between the two tissue compartments. Before the irradiations, we used laser-Doppler flowmetry to confirm that acetazolamide increased cerebral blood flow (CBF) of a rat. We compared means of k 2m , k 2s and k 2, k 3 and k 4 without acetazolamide loading (Rest) and with acetazolamide loading (ACZ). For all k values, ACZ values were lower than Rest values. In other words, though CBF increased, washout rates were decreased. This may be attributed to the implanted (11)C reacting to form (11)CO2. Because acetazolamide increased the concentration of CO2 in brain, suppressed diffusion of (11)CO2 and decomposition of (11)CO2 into ions were prevented.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26863938     DOI: 10.1088/0031-9155/61/5/1875

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Monte Carlo investigation of the characteristics of radioactive beams for heavy ion therapy.

Authors:  Andrew Chacon; Mitra Safavi-Naeini; David Bolst; Susanna Guatelli; Daniel R Franklin; Yuma Iwao; Go Akamatsu; Hideaki Tashima; Eiji Yoshida; Fumihiko Nishikido; Atsushi Kitagawa; Akram Mohammadi; Marie-Claude Gregoire; Taiga Yamaya; Anatoly B Rosenfeld
Journal:  Sci Rep       Date:  2019-04-25       Impact factor: 4.379

2.  Carbon range verification with 718 keV Compton imaging.

Authors:  Raj Kumar Parajuli; Makoto Sakai; Kazuo Arakawa; Yoshiki Kubota; Nobuteru Kubo; Mutsumi Tashiro
Journal:  Sci Rep       Date:  2021-11-04       Impact factor: 4.379

3.  Radioactive Beams in Particle Therapy: Past, Present, and Future.

Authors:  Marco Durante; Katia Parodi
Journal:  Front Phys       Date:  2020-08-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.