The Effect of Different Water Temperatures on Retention Loss and Material Degradation of Locator Attachments.

Lillian Pui Yuk Chiu1, Nicola Di Vitale1, Haralampos Petridis1, Ailbhe McDonald1.   

Abstract

PURPOSE: To examine the changes in Locator attachments after exposure to different water temperatures and cyclic loading.
MATERIALS AND METHODS: Four groups of pink Locator attachments (3.0 lb. light retention replacement patrix attachments; 10 per group) were soaked for the equivalent of 5 years of use in distilled water at the following temperatures: 20°C, 37°C, 60°C. One group was kept dry to test the effect of water. A universal testing machine was used to measure the retention force of each treated attachment during 5500 insertion and removal cycles, simulating approximately 5 years of use. The results were compared using Kruskal-Wallis one-way ANOVA by ranks. Surface changes of tested attachments were examined using scanning electron microscopy (SEM).
RESULTS: The exposure to 60°C water significantly increased the percentage of retention loss in Locator attachments (p < 0.05) compared to the 20°C water group and significantly reduced the final retention force compared to the other groups (p < 0.05). SEM examinations revealed severe cracking and material degradation in Locator attachments after exposure to 60°C water and cyclic loading, which were not evident in other groups. Cracking was observed after exposure to 60˚C water before cyclic loading.
CONCLUSIONS: Exposure to 60°C water, potentially similar to denture cleansing procedures, could cause cracking in Locator attachments. Cracking is associated with hydrolytic degradation of nylon at 60°C. The change in structure could result in a significant loss of retention.
© 2016 by the American College of Prosthodontists.

Entities:  

Keywords:  Dental implants; Locator attachment; overdenture attachment; overdentures; retention; water temperature

Mesh:

Substances:

Year:  2016        PMID: 26861254     DOI: 10.1111/jopr.12440

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

1.  In Vitro Effects of Cyclic Dislodgement on Retentive Properties of Various Titanium-Based Dental Implant Overdentures Attachment System.

Authors:  Tae-Yun Kang; Jee-Hwan Kim; Kwang-Mahn Kim; Jae-Sung Kwon
Journal:  Materials (Basel)       Date:  2019-11-16       Impact factor: 3.623

2.  Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar.

Authors:  Sung-Ki Chae; Won-Tak Cho; Jae-Won Choi; Eun-Bin Bae; Ji-Hyeon Bae; Gang-Ho Bae; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

3.  Effect of Various Retentive Element Materials on Retention of Mandibular Implant-Retained Overdentures.

Authors:  Atitiya Chindarungruangrat; Trinuch Eiampongpaiboon; Bundhit Jirajariyavej
Journal:  Molecules       Date:  2022-06-19       Impact factor: 4.927

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.