Literature DB >> 26861202

MRI T2* imaging for assessment of liver iron overload: study of different data analysis approaches.

El-Sayed H Ibrahim1, Ayman M Khalifa2, Ahmed K Eldaly2.   

Abstract

Background Recently, magnetic resonance imaging (MRI) has been established as an effective technique for evaluating iron overload by measuring T2* in the liver. Purpose To investigate the effects of various factors associated with T2* calculation on the resulting measurement and to determine the analysis criterion that provides the most accurate T2* measurements. Material and Methods Both phantom and in vivo MRI experiments were conducted to study the effects of the selected region of interest (ROI) location and size, signal-averaging method, exponential-fitting model, echo truncation, iron-overload severity, and inter-/intra-observer variabilities on T2* measurements. The results were compared to reference values from the scanner processing software. Results The pixel-by-pixel calculation method provided results in better agreement with the reference values from the MRI scanner than the average or median methods. The choice of the exponential fitting model affected the results, depending on signal-to-noise ratio, number of echoes, minimum and maximum echo times, and tissue composition inside the selected ROI. The single-exponential model resulted in smaller error than the bi-exponential or exponential-plus-constant models, where the latter two models showed similar results. The relative performance of the different models and methods was not affected by the degree of iron-overload. Conclusion Various factors associated with the adopted T2* calculation method affect the resulting measurement. In this study, the pixel-by-pixel calculation method and single-exponential model provided the most accurate results based on the conducted phantom and in vivo MRI experiments.

Entities:  

Keywords:  Magnetic resonance imaging (MRI); T2*; iron overload; iron toxicity; liver

Mesh:

Year:  2016        PMID: 26861202     DOI: 10.1177/0284185116628337

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

Review 1.  Pancreatic iron quantification with MR imaging: a practical guide.

Authors:  Antonella Meloni; Vincenzo Positano; Laura Pistoia; Filippo Cademartiri
Journal:  Abdom Radiol (NY)       Date:  2022-05-21

2.  Comparison of clinical MRI liver iron content measurements using signal intensity ratios, R 2 and R 2.

Authors:  Jurgen H Runge; Erik M Akkerman; Marian A Troelstra; Aart J Nederveen; Ulrich Beuers; Jaap Stoker
Journal:  Abdom Radiol (NY)       Date:  2016-11

3.  Evaluation of Rabbits Liver Fibrosis Using Gd-DTPA-BMA of Dynamic Contrast-Enhanced Magnetic Resonance Imaging.

Authors:  Qian Cui; FengTai He; Jiawei Hu; Shuo Li; Dongmei Guo; Xu Bie; Wei Liu; Yiping Zhao
Journal:  Evid Based Complement Alternat Med       Date:  2021-09-17       Impact factor: 2.629

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.