Literature DB >> 26860917

An Automatic 3-D Reconstruction of Coronary Arteries by Stereopsis.

Mufit Cetin1, Ali Iskurt2.   

Abstract

Stereopsis of X-ray images can produce 3D tree of coronary arteries up to a certain accuracy level with a lower dose of radiation when compared to computer tomography (CT). In this study, a novel and complete automatic system is designed that covers preprocessing, segmentation, matching and reconstruction steps for that purpose. First, an automatic and novel pattern recognition technique is applied for extraction of the bifurcation points with their diameters recorded in a map. Then, a novel optimization algorithm is run for matching the branches efficiently which is based on that map and the epipolar geometry of stereopsis. Finally, cut branches are fixed one by one at the bifurcations for completing the 3D reconstruction. This method prevails the similar ones in the literature with this novelty since it automatically and inherently prevents the wrong overlapping of branches. Other essential problems like correct detection of the bifurcations and accurate calibration parameters and fast overlapping of matched branches are addressed at acceptable levels. The accuracy of bifurcation extraction is high at 90 % with 96 % sensitivity. Accuracy of vessel centerlines has rootmean-square (rms) error smaller than 0.57 mm for 20 different patients. For phantom model, rms error is 0.75 ± 0.8 mm in 3D localization.

Entities:  

Keywords:  Automaticity; Bifurcation; Coronary artery; Medical imaging; Stereopsis

Mesh:

Year:  2016        PMID: 26860917     DOI: 10.1007/s10916-016-0455-z

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  17 in total

1.  Novel approach for 3-d reconstruction of coronary arteries from two uncalibrated angiographic images.

Authors:  Jian Yang; Yongtian Wang; Yue Liu; Songyuan Tang; Wufan Chen
Journal:  IEEE Trans Image Process       Date:  2009-05-02       Impact factor: 10.856

2.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

3.  3-D reconstruction of the coronary artery tree from multiple views of a rotational X-ray angiography.

Authors:  Rui Liao; Duong Luc; Yiyong Sun; Klaus Kirchberg
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-03       Impact factor: 2.357

Review 4.  Radiation dose to patients from cardiac diagnostic imaging.

Authors:  Andrew J Einstein; Kevin W Moser; Randall C Thompson; Manuel D Cerqueira; Milena J Henzlova
Journal:  Circulation       Date:  2007-09-11       Impact factor: 29.690

5.  Automatic identification of landmarks for standard slice positioning in brain MRI.

Authors:  Ali Iskurt; Yasar Becerikli; Kamran Mahmutyazicioglu
Journal:  J Magn Reson Imaging       Date:  2011-07-12       Impact factor: 4.813

6.  Multiresolution image registration in digital x-ray angiography with intensity variation modeling.

Authors:  Mansour Nejati; Hossein Pourghassem
Journal:  J Med Syst       Date:  2014-01-28       Impact factor: 4.460

7.  Accuracy of coronary CT angiography using a submillisievert fraction of radiation exposure: comparison with invasive coronary angiography.

Authors:  Julia Stehli; Tobias A Fuchs; Sacha Bull; Olivier F Clerc; Mathias Possner; Ronny R Buechel; Oliver Gaemperli; Philipp A Kaufmann
Journal:  J Am Coll Cardiol       Date:  2014-08-26       Impact factor: 24.094

8.  Automatic segmentation of coronary angiograms based on fuzzy inferring and probabilistic tracking.

Authors:  Zhou Shoujun; Yang Jian; Wang Yongtian; Chen Wufan
Journal:  Biomed Eng Online       Date:  2010-08-20       Impact factor: 2.819

Review 9.  Dedicated bifurcation analysis: basic principles.

Authors:  Joan C Tuinenburg; Gerhard Koning; Andrei Rareş; Johannes P Janssen; Alexandra J Lansky; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-17       Impact factor: 2.357

10.  Assessment of obstruction length and optimal viewing angle from biplane X-ray angiograms.

Authors:  Shengxian Tu; Gerhard Koning; Wouter Jukema; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-18       Impact factor: 2.357

View more
  2 in total

1.  A Visualization System for Interactive Exploration of the Cardiac Anatomy.

Authors:  Lei Zhang; Kuanquan Wang; Fei Yang; Wenjing Lu; Kechao Wang; Yue Zhang; Xiaoqing Liang; Dongchen Han; Ying Julie Zhu
Journal:  J Med Syst       Date:  2016-04-20       Impact factor: 4.460

2.  HOSVD-Based 3D Active Appearance Model: Segmentation of Lung Fields in CT Images.

Authors:  Qingzhu Wang; Wanjun Kang; Haihui Hu; Bin Wang
Journal:  J Med Syst       Date:  2016-06-08       Impact factor: 4.460

  2 in total