Literature DB >> 26859645

Application of a Sub-set of Skinfold Sites for Ultrasound Measurement of Subcutaneous Adiposity and Percentage Body Fat Estimation in Athletes.

D C O'Neill1, O Cronin2, S B O'Neill3, T Woods3, D M Keohane2, M G Molloy2, E C Falvey2.   

Abstract

Body composition assessment is an integral feature of elite sport as optimization facilitates successful performance. This study aims to refine the use of B-mode ultrasound in the assessment of athlete body composition by determining suitable sites for measurement. 67 elite athletes recruited from the Human Performance Laboratory, University College Cork, Ireland, underwent dual measurement of body composition. Subcutaneous adipose tissue thickness at 7 anatomical sites were measured using ultrasound and compared to percentage body fat values determined using Dual-Energy X-ray Absorptiometry. Multiple linear regressions were performed and an equation to predict percentage body fat was derived. The present study found subcutaneous adipose tissue depths at the triceps, biceps, anterior thigh and supraspinale sites correlated significantly with percentage body fat by X-ray absorptiometry (all p<0.05). Summation of the depths at these locations correlated strongly with percentage body fat by Dual-Energy X-ray Absorptiometry (R²=0.879). The triceps, biceps, anterior thigh and supraspinale sites are suitable anatomical landmarks for the estimation of %BF using B-mode ultrasound. Use of B-mode ultrasound in the assessment of athlete body composition confers many benefits including lack of ionising radiation and its potential to be used as a portable field tool. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2016        PMID: 26859645     DOI: 10.1055/s-0035-1565168

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  4 in total

1.  Utility of ultrasound for body fat assessment: validity and reliability compared to a multicompartment criterion.

Authors:  Abbie E Smith-Ryan; Malia N M Blue; Eric T Trexler; Katie R Hirsch
Journal:  Clin Physiol Funct Imaging       Date:  2016-12-16       Impact factor: 2.273

2.  Agreement Between A 2-Dimensional Digital Image-Based 3-Compartment Body Composition Model and Dual Energy X-Ray Absorptiometry for The Estimation of Relative Adiposity.

Authors:  Katherine Sullivan; Casey J Metoyer; Bjoern Hornikel; Clifton J Holmes; Brett S Nickerson; Michael R Esco; Michael V Fedewa
Journal:  J Clin Densitom       Date:  2021-09-24       Impact factor: 2.963

3.  Assessing subcutaneous adipose tissue by simple and portable field instruments: Skinfolds versus A-mode ultrasound measurements.

Authors:  Carla Pérez-Chirinos Buxadé; Toni Solà-Perez; Jorge Castizo-Olier; Marta Carrasco-Marginet; Alex Roy; Michael Marfell-Jones; Alfredo Irurtia
Journal:  PLoS One       Date:  2018-11-29       Impact factor: 3.240

4.  Correlation of Subcutaneous Fat Measured on Ultrasound with Body Mass Index.

Authors:  Baby Nadeem; Raham Bacha; Syed Amir Gilani
Journal:  J Med Ultrasound       Date:  2018-12-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.