Literature DB >> 26858809

Measurements of flow-induced birefringence in microfluidics.

Chen-Li Sun1, Hung-Yen Huang1.   

Abstract

In this study, we demonstrate the use of a microscopic circular polariscope to measure the flow-induced birefringence in a microfluidic device that represents the kinematics of fluid motion optically. Unlike the commercial birefringence microscope employed in the previous studies, our approach is able to provide direct measurement of retardance, which quantifies the difference in refractive index of the fluid experienced by the ordinary and extraordinary rays, from one single image frame. This capability facilitates unsteady full-field quantitation of flow-induced birefringence in microfluidics that has never been achieved before. At low flow rates, we find that the value of the retardance is independent of the microfluidic design and proportional to the nominal strain rates. This linearity bridges the measurement of birefringence and the deformation rate in the microflow environment, which yields the stress information of the fluid flow. In addition, the μPIV results confirm that both extensional and shear strain rates contribute to the flow-induced birefringence so that the retardance distribution can be used to represent the field of the principal strain rate in a microfluidic device. The outcome of this study proves that our approach provides a non-invasive method that enables an intuitive full-field representation of stress in the instantaneous flow field in a microfluidic device.

Entities:  

Year:  2016        PMID: 26858809      PMCID: PMC4714985          DOI: 10.1063/1.4939949

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  4 in total

1.  Depth-resolved birefringence and differential optical axis orientation measurements with fiber-based polarization-sensitive optical coherence tomography.

Authors:  Shuguang Guo; Jun Zhang; Lei Wang; J Stuart Nelson; Zhongping Chen
Journal:  Opt Lett       Date:  2004-09-01       Impact factor: 3.776

2.  Nonlocal effects in flows of wormlike micellar solutions.

Authors:  Chloé Masselon; Jean-Baptiste Salmon; Annie Colin
Journal:  Phys Rev Lett       Date:  2008-01-25       Impact factor: 9.161

3.  Stagnation point flow of wormlike micellar solutions in a microfluidic cross-slot device: effects of surfactant concentration and ionic environment.

Authors:  Simon J Haward; Gareth H McKinley
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2012-03-14

4.  Accurate blood flow measurements: are artificial tracers necessary?

Authors:  Christian Poelma; Astrid Kloosterman; Beerend P Hierck; Jerry Westerweel
Journal:  PLoS One       Date:  2012-09-20       Impact factor: 3.240

  4 in total
  2 in total

1.  Preface to Special Topic: Selected Papers from the 5th International Conference on Optofluidics.

Authors:  Shih-Kang Fan; Zhenchuan Yang
Journal:  Biomicrofluidics       Date:  2016-02-29       Impact factor: 2.800

2.  Simple multi-wavelength imaging of birefringence:case study of silk.

Authors:  Reo Honda; Meguya Ryu; Jing-Liang Li; Vygantas Mizeikis; Saulius Juodkazis; Junko Morikawa
Journal:  Sci Rep       Date:  2018-12-05       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.