Literature DB >> 26856427

Correlational Analysis of Objective and Subjective Measures of Cataract Quantification.

Béatrice Cochener, Sunni R Patel, Florence Galliot.   

Abstract

PURPOSE: To evaluate whether correlations exist between objective and subjective measures of vision quality as a consequence of cataract and whether this may qualify the Objective Scatter Index as a supplementary means of cataract assessment.
METHODS: A prospective multicenter, cross-sectional study was conducted in 10 centers across France in patients undergoing cataract extraction surgery (lens opacity evaluated with the Lens Opacities Classification System III). A quality of life assessment using the Visual Function Index-14 (VF-14) (14 questions scored from 0 to 4) and measurement of visual acuity and evaluation of the Objective Scatter Index (HD Analyzer, Visiometrics SL, Terrassa, Spain) to assess the alteration of light scatter were used as measures in the study.
RESULTS: The study included 1,768 eyes of 1,768 patients (mean age: 72.5 years; range: 28 to 93 years). The average OSI score was 4.97 ± 3.13 (range: 0.4 to 20.5). There was good correlation between visual acuity and OSI (r = -0.47, P < .001) and between OSI and VF-14 (r = -0.11, P < .001).
CONCLUSIONS: The results presented in this study confirm that the Objective Scatter Index has sufficient correlations with visual acuity and VF-14 to supplement existing cataract diagnosis in a large population encompassing a broad spectrum of cataract presentations. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 26856427     DOI: 10.3928/1081597X-20151222-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

Review 1.  From Presbyopia to Cataracts: A Critical Review on Dysfunctional Lens Syndrome.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  J Ophthalmol       Date:  2018-06-27       Impact factor: 1.909

2.  Near Vision Improvement with the Use of a New Topical Compound for Presbyopia Correction: A Prospective, Consecutive Interventional Non-Comparative Clinical Study.

Authors:  Veronica Vargas; Felipe Vejarano; Jorge L Alió
Journal:  Ophthalmol Ther       Date:  2018-11-21

3.  Correlation among Lens Opacities Classification System III grading, the 25-item National Eye Institute Visual Functioning Questionnaire, and Visual Function Index-14 for age-related cataract assessment.

Authors:  Yu Wan; Yinhao Wang; Liming Zhao; Min Sun; Li An; Yang Yang; Aimin Jiang; Yanhui Xu; Zhimin Chen; Xuemin Li
Journal:  Int Ophthalmol       Date:  2020-04-05       Impact factor: 2.031

4.  Using Optical Quality Analysis System for predicting surgical parameters in age-related cataract patients.

Authors:  Thibaud Garcin; Damien Grivet; Gilles Thuret; Philippe Gain
Journal:  PLoS One       Date:  2020-10-12       Impact factor: 3.240

  4 in total