Literature DB >> 26855840

Scaphoid Proximal Pole Fracture Following Headless Screw Fixation.

Schneider K Rancy1, Jonathan A Zelken1, Joseph D Lipman2, Scott W Wolfe1.   

Abstract

Background Headless screw fixation of scaphoid fractures and nonunions yields predictably excellent outcomes with a relatively low complication profile. However, intramedullary implants affect the load to failure and stress distribution within bone and may be implicated in subsequent fracture. Case Description We describe a posttraumatic fracture pattern of the scaphoid proximal pole originating at the previous headless screw insertion site in three young male patients with healed scaphoid nonunions. Each fracture was remarkably similar in shape and size, comprised the volar proximal pole, and was contiguous with the screw entry point. Treatment was challenging but successful in all cases. Literature Review Previous reports have posited that stress-raisers secondary to screw orientation may be implicated in subsequent peri-implant fracture of the femoral neck. Repeat scaphoid fracture after screw fixation has also been reported. However, the shape and locality of secondary fracture have not been described, nor has the potential role of screw fixation in the production of distinct fracture patterns. Clinical Relevance Hand surgeons must be aware of this difficult complication that may follow antegrade headless screw fixation of scaphoid fracture nonunion, and of available treatment strategies.

Entities:  

Keywords:  complication; internal fixation; peri-implant; refracture; scaphoid nonunion

Year:  2015        PMID: 26855840      PMCID: PMC4742264          DOI: 10.1055/s-0035-1565928

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  21 in total

1.  Open reduction and internal fixation of acute displaced scaphoid waist fractures.

Authors:  M E Rettig; S H Kozin; W P Cooney
Journal:  J Hand Surg Am       Date:  2001-03       Impact factor: 2.230

2.  Biomechanical measurements on scaphoid bone screws in an experimental model.

Authors:  D M Kaulesar Sukul; E J Johannes; R K Marti; P J Klopper
Journal:  J Biomech       Date:  1990       Impact factor: 2.712

3.  A biomechanical comparison of two patterns of screw insertion.

Authors:  Sheldon Lichtblau; Jessica Gallina; Philip Nasser; Musyoka Munyoki; Karl Jepsen
Journal:  Bull NYU Hosp Jt Dis       Date:  2008

4.  Biomechanical comparison of fixation devices in experimental scaphoid osteotomies.

Authors:  F M Carter; M C Zimmerman; D M DiPaola; R P Mackessy; J R Parsons
Journal:  J Hand Surg Am       Date:  1991-09       Impact factor: 2.230

5.  Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures.

Authors:  C D Bond; A Y Shin; M T McBride; K D Dao
Journal:  J Bone Joint Surg Am       Date:  2001-04       Impact factor: 5.284

6.  Mechanical strength and optimal site of placement of a threaded bone screw assessed on the basis of the screw breakage for non-union of the scaphoid: a biomechanical study.

Authors:  Katsumi Takase; Kengo Yamamoto
Journal:  Hand Surg       Date:  2005

7.  Percutaneous cannulated screw fixation of acute scaphoid waist fracture.

Authors:  H S F Yip; W C Wu; R Y P Chang; T Y C So
Journal:  J Hand Surg Br       Date:  2002-02

8.  A review of scaphoid fracture healing in competitive athletes.

Authors:  J N Riester; B E Baker; J F Mosher; D Lowe
Journal:  Am J Sports Med       Date:  1985 May-Jun       Impact factor: 6.202

9.  Nonoperative compared with operative treatment of acute scaphoid fractures. A randomized clinical trial.

Authors:  Bertil Vinnars; Mihai Pietreanu; Ake Bodestedt; Fredrik af Ekenstam; Bengt Gerdin
Journal:  J Bone Joint Surg Am       Date:  2008-06       Impact factor: 5.284

10.  [Central placement of screw fixation for scaphoid fracture: a biomechanical study].

Authors:  Yang Guo; Guang-Lei Tian; Bao-Guo Jiang; Shan-Lin Chen; Na Han
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2013-10-18
View more
  1 in total

1.  Can headless screw used in fixation of the scaphoid proximal pole fracture be broken after wrist trauma? An unreported complication of scaphoid surgery.

Authors:  Uğur Bezirgan; Erdinç Acar; Emre Anıl Özbek
Journal:  Jt Dis Relat Surg       Date:  2021-11-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.