Literature DB >> 26854936

Planar biaxial testing of soft biological tissue using rakes: A critical analysis of protocol and fitting process.

Heleen Fehervary1, Marija Smoljkić2, Jos Vander Sloten2, Nele Famaey2.   

Abstract

Mechanical characterization of soft biological tissue is becoming more and more prevalent. Despite the growing use of planar biaxial testing for soft tissue characterization, testing conditions and subsequent data analysis have not been standardized and vary widely. This also influences the quality of the result of the parameter fitting. Moreover, the testing conditions and data analysis are often not or incompletely reported, which impedes the proper comparison of parameters obtained from different studies. With a focus on planar biaxial tests using rakes, this paper investigates varying testing conditions and varying data analysis methods and their effect on the quality of the parameter fitting results. By means of a series of finite element simulations, aspects such as number of rakes, rakes׳ width, loading protocol, constitutive model, material stiffness and anisotropy are evaluated based on the degree of homogeneity of the stress field, and on the correlation between the experimentally obtained stress and the stress derived from the constitutive model. When calculating the aforementioned stresses, different definitions of the section width and deformation gradient are used in literature, each of which are looked into. Apart from this degree of homogeneity and correlation, also the effect on the quality of the parameter fitting result is evaluated. The results show that inhomogeneities can be reduced to a minimum for wise choices of testing conditions and analysis methods, but never completely eliminated. Therefore, a new parameter optimization procedure is proposed that corrects for the inhomogeneities in the stress field and induces significant improvements to the fitting results. Recommendations are made for best practice in rake-based planar biaxial testing of soft biological tissues and subsequent parameter fitting, and guidelines are formulated for reporting thereof in publications.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Keywords:  Constitutive modelling; FE simulations; Inhomogeneity; Parameter fitting; Planar biaxial testing

Mesh:

Year:  2016        PMID: 26854936     DOI: 10.1016/j.jmbbm.2016.01.011

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  Mechanical and structural changes in human thoracic aortas with age.

Authors:  Majid Jadidi; Mahmoud Habibnezhad; Eric Anttila; Kaspars Maleckis; Anastasia Desyatova; Jason MacTaggart; Alexey Kamenskiy
Journal:  Acta Biomater       Date:  2019-12-23       Impact factor: 8.947

2.  Evaluation of Pericardial Tissues from Assorted Species as a Tissue-Engineered Heart Valve Material.

Authors:  Christopher Noble; David Morse; Amir Lerman; Melissa Young
Journal:  Med Biol Eng Comput       Date:  2022-01-04       Impact factor: 2.602

3.  Biaxial testing system for characterization of mechanical and rupture properties of small samples.

Authors:  Andrea Corti; Tariq Shameen; Shivang Sharma; Annalisa De Paolis; Luis Cardoso
Journal:  HardwareX       Date:  2022-06-28

4.  Mechanical and finite element evaluation of a bioprinted scaffold following recellularization in a rat subcutaneous model.

Authors:  Christopher Noble; Eva L Maxson; Amir Lerman; Melissa D Young
Journal:  J Mech Behav Biomed Mater       Date:  2019-11-09

5.  An Optimum Specimen Geometry for Equibiaxial Experimental Tests of Reinforced Magnetorheological Elastomers with Iron Micro- and Nanoparticles.

Authors:  Luis Manuel Palacios-Pineda; Imperio Anel Perales-Martínez; Mario Regino Moreno-Guerra; Alex Elías-Zúñiga
Journal:  Nanomaterials (Basel)       Date:  2017-09-03       Impact factor: 5.076

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.