Literature DB >> 26853685

The applied research of MRI with ASSET-EPI-FLAIR combined with 3D TOF MRA sequences in the assessment of patients with acute cerebral infarction.

Zhichao Lin1, Zexiong Guo2, Lin Qiu3, Wanyoug Yang1, Mingxia Lin1.   

Abstract

Background To extend the time window for thrombolysis, reducing the time for diagnosis and detection of acute cerebral infarction seems to be warranted. Purpose To evaluate the feasibility of implementing an array spatial sensitivity technique (ASSET)-echo-planar imaging (EPI)-fluid attenuated inversion recovery (FLAIR) (AE-FLAIR) sequence into an acute cerebral infarction magnetic resonance (MR) evaluation protocol, and to assess the diagnostic value of AE-FLAIR combined with three-dimensional time-of-flight MR angiography (3D TOF MRA). Material and Methods A total of 100 patients (68 men, 32 women; age range, 44-82 years) with acute cerebral infarction, including 50 consecutive uncooperative and 50 cooperative patients, were evaluated with T1-weighted (T1W) imaging, T2-weighted (T2W) imaging, FLAIR, diffusion-weighted imaging (DWI), 3D TOF, EPI-FLAIR, and AE-FLAIR. Conventional FLAIR, EPI-FLAIR, and AE-FLAIR were assessed by two observers independently for image quality. The optimized group (AE-FLAIR and 3D TOF) and the control group (T1W imaging, T2W imaging, conventional FLAIR, DWI, and 3D TOF) were compared for evaluation time and diagnostic accuracy. Results One hundred and twenty-five lesions were detected and images having adequate diagnostic image quality were in 73% of conventional FLAIR, 62% of EPI-FLAIR, and 89% of AE-FLAIR. The detection time was 12 ± 1 min with 76% accuracy and 4 ± 0.5 min with 100% accuracy in the control and the optimized groups, respectively. Inter-observer agreements of κ = 0.78 and κ = 0.81 were for the optimized group and control group, respectively. Conclusion With reduced acquisition time and better image quality, AE-FLAIR combined with 3D TOF may be used as a rapid diagnosis tool in patients with acute cerebral infarction, especially in uncooperative patients.

Entities:  

Keywords:  Acute cerebral infarction; fluid attenuated inversion recovery (FLAIR); image quality; magnetic resonance imaging (MRI); three-dimensional time-of-flight magnetic resonance angiography (3D TOF MRA)

Mesh:

Year:  2016        PMID: 26853685     DOI: 10.1177/0284185116628338

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  1 in total

1.  Reliability of fast magnetic resonance imaging for acute ischemic stroke patients using a 1.5-T scanner.

Authors:  Mi Sun Chung; Ji Ye Lee; Seung Chai Jung; Seunghee Baek; Woo Hyun Shim; Ji Eun Park; Ho Sung Kim; Choong Gon Choi; Sang Joon Kim; Deok Hee Lee; Sang-Beom Jeon; Dong-Wha Kang; Sun U Kwon; Jong S Kim
Journal:  Eur Radiol       Date:  2018-11-12       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.