Complete dentures were made for 30 patients. Fifteen sets were processed by conventional compression molding and 15 sets were processed by using the SR-Ivocap injection system. Changes in vertical dimension between the waxed and processed dentures were measured at the incisal guide pin by using a dial indicator. The difference between the two methods was highly significant on the basis of t-test statistics. Whereas the processing changes noted with the conventional pack-and-press method were similar to previous studies, the injection method produced little or no pin opening. The superiority of the injection method before decasting was indisputable, and the results suggest that the laboratory remount procedure may be unnecessary when this system is used.Entities: