Literature DB >> 26851063

Accuracy of bedside ultrasonography for the diagnosis of finger fractures.

Ersin Aksay1, Turgay Yılmaz Kilic2, Murat Yesılaras3, Feriyde Calıskan Tur3, Mustafa Sever3, Onder Kalenderer4.   

Abstract

OBJECTIVE: Diagnosis of bone fractures by ultrasonography is becoming increasingly popular in emergency medicine practice. We aimed to determine the diagnostic sensitivity and specificity of point-of-care ultrasonography (PoCUS) compared with plain radiographs in proximal and middle phalanx fractures.
METHODS: Between August 2012 and July 2013, adult patients presenting to our emergency department with a possible (by clinical evaluation) proximal or middle phalanx fracture of finger were invited to participate in this prospective cohort study. From those granting consent to participate, anteroposterior and lateral radiographs were obtained. PoCUS was then performed by emergency physicians blinded to the radiograph results. The criterion standard test for diagnosis was radiograph interpretation by an orthopedic surgeon blinded to the ultrasonographic findings.
RESULTS: During the study period, 212 patients with an injury to the proximal or middle phalanx presented to the emergency department. Of these, 93 patients met exclusion criteria; thus, data were analyzed from the remaining 119 patients. Fracture prevalence was 24.3%. Diagnostic sensitivity of PoCUS was 79.3% (95% confidence interval [CI], 59.7%-91.2%), specificity was 90% (95% CI, 81.4%-95.0%), positive predictive value was 71.8% (95% CI, 53.0%-85.6%), negative predictive value was 93.1% (95% CI, 85.0%-97.1%), positive likelihood ratio was 7.93 (95% CI, 4.15-15), and negative likelihood ratio was 0.23 (95% CI, 0.11-0.47).
CONCLUSION: Emergency physician-performed PoCUS was moderately sensitive and specific for diagnosing proximal and middle phalanx fractures.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26851063     DOI: 10.1016/j.ajem.2016.01.010

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  7 in total

Review 1.  Clinical indications for musculoskeletal ultrasound updated in 2017 by European Society of Musculoskeletal Radiology (ESSR) consensus.

Authors:  Luca Maria Sconfienza; Domenico Albano; Georgina Allen; Alberto Bazzocchi; Bianca Bignotti; Vito Chianca; Fernando Facal de Castro; Elena E Drakonaki; Elena Gallardo; Jan Gielen; Andrea Sabine Klauser; Carlo Martinoli; Giovanni Mauri; Eugene McNally; Carmelo Messina; Rebeca Mirón Mombiela; Davide Orlandi; Athena Plagou; Magdalena Posadzy; Rosa de la Puente; Monique Reijnierse; Federica Rossi; Saulius Rutkauskas; Ziga Snoj; Jelena Vucetic; David Wilson; Alberto Stefano Tagliafico
Journal:  Eur Radiol       Date:  2018-06-06       Impact factor: 5.315

2.  The Investigation of Suspected Fracture-a Comparison of Ultrasound With Conventional Imaging.

Authors:  Gordian Lukas Schmid; Stefan Lippmann; Susanne Unverzagt; Christiane Hofmann; Tobias Deutsch; Thomas Frese
Journal:  Dtsch Arztebl Int       Date:  2017-11-10       Impact factor: 5.594

3.  The effectiveness of ultrasound in the detection of fractures in adults with suspected upper or lower limb injury: a systematic review and subgroup meta-analysis.

Authors:  Natalie Champagne; Leila Eadie; Luke Regan; Philip Wilson
Journal:  BMC Emerg Med       Date:  2019-01-28

4.  Value of Ultrasound-Guided Closed Reduction and Minimally Invasive Fixation in the Treatment of Metacarpal Fractures.

Authors:  Suhong Shen; Xiaohui Wang; Zhuo Fu
Journal:  J Ultrasound Med       Date:  2019-02-21       Impact factor: 2.153

5.  The value of ultrasound for detecting hand fractures: A meta-analysis.

Authors:  Wenjun Zhao; Gang Wang; Binjuan Chen; Jihong Xiao; Xiaoping Sun; Tingting Wu; Haijun Ren; Xingjie Li
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.889

6.  The Use of Ultrasound to Exclude Extremity Fractures in Adults.

Authors:  Kaj Døssing; Inger Mechlenburg; Lars Bolvig Hansen; Kjeld Søballe; Helle Østergaard
Journal:  JB JS Open Access       Date:  2017-08-10

Review 7.  Point-of-care ultrasound in primary care: a systematic review of generalist performed point-of-care ultrasound in unselected populations.

Authors:  Bjarte Sorensen; Steinar Hunskaar
Journal:  Ultrasound J       Date:  2019-11-19
  7 in total