Literature DB >> 2684264

Magnets and orthodontics.

P J Sandler1, S Meghji, A M Murray, S D Springate, J R Sandy, V Crow, R T Reed.   

Abstract

The first part of this paper is a literature review of magnets and their uses in orthodontics. The biological safety of magnets is considered and a report is given of experiments carried out on rat osteosarcoma cell line UMR-106. The second part of the paper describes a case where neodynium-iron-boron magnets were used to assist eruption of an unerupted, vertically impacted upper right canine. Previously, space was available for this tooth, but it failed to show signs of eruption. Following surgical attachment of a magnet, and the use of a second magnet attached to an upper removable appliance, rapid eruption occurred producing a favourable position for bonding.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2684264     DOI: 10.1179/bjo.16.4.243

Source DB:  PubMed          Journal:  Br J Orthod        ISSN: 0301-228X


  2 in total

1.  Cytotoxic effect of indigenously fabricated dental magnets for application in prosthodontics.

Authors:  Satyabodh Shesharaj Guttal; Ramesh K Nadiger; Pravinkumar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

2.  Case Presentation of Two Maxillectomy Patients Restored with Two-piece Hollow Bulb Obturator Retained using Two Different Types of Magnets.

Authors:  B Devi Parameswari; M Rajakumar; N Jagadesaan; H Annapoorni
Journal:  J Pharm Bioallied Sci       Date:  2017-11
  2 in total