Literature DB >> 26842266

Pesticide analysis using nanoceria-coated paper-based devices as a detection platform.

Souksanh Nouanthavong1, Duangjai Nacapricha2, Charles S Henry3, Yupaporn Sameenoi4.   

Abstract

We report the first use of a paper-based device coated with nanoceria as a simple, low-cost and rapid detection platform for the analysis of organophosphate (OP) pesticides using an enzyme inhibition assay with acetylcholinesterase (AChE) and choline oxidase (ChOX). In the presence of acetylcholine, AChE and ChOX catalyze the formation of H2O2, which is detected colorimetrically by a nanoceria-coated device resulting in the formation of a yellow color. After incubation with OP pesticides, the AChE activity was inhibited, producing less H2O2, and a reduction in the yellow intensity. The assay is able to analyze OP pesticides without the use of sophisticated instruments and gives detection limits of 18 ng mL(-1) and 5.3 ng mL(-1) for methyl-paraoxon and chlorpyrifos-oxon, respectively. The developed method was successfully applied to detect methyl-paraoxon in spiked vegetables (cabbage) and a dried seafood product (dried green mussel), obtaining ∼95% recovery values for both sample types. The spiked samples were also analyzed using LC-MS/MS as a comparison to the developed method and similar values were obtained, indicating that the developed method gives accurate results and is suitable for OP analysis in real samples.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26842266     DOI: 10.1039/c5an02403j

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  14 in total

Review 1.  Point-of-care testing in the early diagnosis of acute pesticide intoxication: The example of paraquat.

Authors:  Ting-Yen Wei; Tzung-Hai Yen; Chao-Min Cheng
Journal:  Biomicrofluidics       Date:  2018-01-19       Impact factor: 2.800

2.  Modification of Microfluidic Paper-Based Devices with an Oxidant Layer for Distance Readout of Reducing Substances.

Authors:  Chunxiu Xu; Guoxing Zhou; Huihui Cai; Yicong Chen; Ling Huang; Longfei Cai; Jiaye Gong; Zankai Yan
Journal:  ACS Omega       Date:  2022-06-02

3.  Paper-based diagnostic devices for clinical paraquat poisoning diagnosis.

Authors:  Chen-Meng Kuan; Szu-Ting Lin; Tzung-Hai Yen; Yu-Lin Wang; Chao-Min Cheng
Journal:  Biomicrofluidics       Date:  2016-06-21       Impact factor: 2.800

4.  Smartphone-coupled three-layered paper-based microfluidic chips demonstrating stereoscopic capillary-driven fluid transport towards colorimetric detection of pesticides.

Authors:  Hongjiao Wu; Jiaqi Chen; Yi Yang; Weitai Yu; Ying Chen; Pengcheng Lin; Ke Liang
Journal:  Anal Bioanal Chem       Date:  2022-01-21       Impact factor: 4.142

5.  Preparation of Hydrophobic Film by Electrospinning for Rapid SERS Detection of Trace Triazophos.

Authors:  Fei Shao; Jiaying Cao; Ye Ying; Ying Liu; Dan Wang; Xiaoyu Guo; Yiping Wu; Ying Wen; Haifeng Yang
Journal:  Sensors (Basel)       Date:  2020-07-24       Impact factor: 3.576

Review 6.  Detecting Chemical Hazards in Foods Using Microfluidic Paper-Based Analytical Devices (μPADs): The Real-World Application.

Authors:  Marti Z Hua; Shenmiao Li; Shuo Wang; Xiaonan Lu
Journal:  Micromachines (Basel)       Date:  2018-01-17       Impact factor: 2.891

Review 7.  Advances in Microfluidic Paper-Based Analytical Devices for Food and Water Analysis.

Authors:  Lori Shayne Alamo Busa; Saeed Mohammadi; Masatoshi Maeki; Akihiko Ishida; Hirofumi Tani; Manabu Tokeshi
Journal:  Micromachines (Basel)       Date:  2016-05-09       Impact factor: 2.891

Review 8.  Advanced Signal-Amplification Strategies for Paper-Based Analytical Devices: A Comprehensive Review.

Authors:  Thi Xoan Hoang; Le Minh Tu Phan; Thuy Anh Thu Vo; Sungbo Cho
Journal:  Biomedicines       Date:  2021-05-12

9.  Instrument-free detection of polyphenols with a thread-based analytical device.

Authors:  Jiahong Song; Zhuang Ouyang; Wei Lu; Longfei Cai
Journal:  R Soc Open Sci       Date:  2020-03-11       Impact factor: 2.963

10.  A Hybrid Lab-on-a-Chip Injector System for Autonomous Carbofuran Screening.

Authors:  Aristeidis S Tsagkaris; Jana Pulkrabova; Jana Hajslova; Daniel Filippini
Journal:  Sensors (Basel)       Date:  2019-12-17       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.