Literature DB >> 26841140

Validity of Asthma Control Test in Assessing Asthma Control in Czech Outpatient Setting.

Elena Gurková1, Patrice Popelková2.   

Abstract

AIM: The aim of the study was to determine the reliability and validity of the agreement between the Asthma Control Test (ACT) and Global Initiative for Asthma (GINA) in classifying asthma control in the Czech Republic.
METHODS: A sample of 316 people with asthma was recruited from the Clinic of Tuberculosis and Respiratory Diseases of the University Hospital in Ostrava between November 2011 and July 2012. Two questionnaires were used in this study, the Asthma Control Test and Mini Asthma Quality of Life Questionnaire (Mini-AQLQ). Regardless of the questionnaire results the asthma specialist assessed the asthma control status of enlisted patients according to the criteria described in the GINA 2006 guidelines.
RESULTS: The internal consistency of the five-item ACT was good. The ACT score of ≥20 predicted GINA-defined controlled asthma in 29% of cases with a sensitivity of 65% and specificity of 89%. The kappa level of agreement between the ACT classification and GINA classification of asthma control was 0.29, suggesting fair agreement. The ACT score showed the strongest correlation with the specialists' rating, followed by the FEV1 percent predicted. Overall, in line with previous studies we confirmed significant relationship between the ACT scores and FEV1 and health related quality of life.
CONCLUSIONS: ACT is a reliable and simple tool that might be a significant asset in the management of outpatients with asthma in the Czech Republic. The ACT score correlates well with lung function parameters and health related quality of life. It appears to be a good tool to predict GINA-defined 'not-controlled asthma'. Copyright© by the National Institute of Public Health, Prague 2015.

Entities:  

Keywords:  Czech Republic; GINA guidelines; asthma control; asthma control test

Mesh:

Year:  2015        PMID: 26841140     DOI: 10.21101/cejph.a4056

Source DB:  PubMed          Journal:  Cent Eur J Public Health        ISSN: 1210-7778            Impact factor:   1.163


  2 in total

1.  Relationship between Fractional Exhaled Nitric Oxide Level and Efficacy of Inhaled Corticosteroid in Asthma-COPD Overlap Syndrome Patients with Different Disease Severity.

Authors:  Jia Xi Feng; Yun Lin; Jian Lin; Su Su He; Mei Fang Chen; Xiao Mai Wu; You Zu Xu
Journal:  J Korean Med Sci       Date:  2017-03       Impact factor: 2.153

Review 2.  Relationship between the Asthma Control Test (ACT) and other outcomes: a targeted literature review.

Authors:  Bas C P van Dijk; Henrik Svedsater; Andreas Heddini; Linda Nelsen; Janita S Balradj; Cathelijne Alleman
Journal:  BMC Pulm Med       Date:  2020-04-03       Impact factor: 3.317

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.