Literature DB >> 26840270

Success Rate of Two-Piece Zirconia Implants: A Retrospective Statistical Analysis.

Siegfried Jank1, Gregor Hochgatterer.   

Abstract

PURPOSE: About 10 years ago, one-piece zirconia implants were introduced to dentistry. The aim of the study was to evaluate the clinical success of two-piece zirconia implants regarding osseointegration using the manufacturers' warranty data.
MATERIALS AND METHODS: Over a period of 4 years (2010-2014), the data of warranty replacements of 15,255 sold Zeramex implants were evaluated retrospectively and blinded.
RESULTS: Three hundred forty-seven (2.2%) nonosseointegrated implants were sent back. Zeramex T showed an average success rate of 96.7%, whereas Zeralock implants exhibited an average success rate of 98.5%. Furthermore, Zeramex Plus implants exhibit an average success rate of 99.4% within the investigated period. Assuming, that 2% of the failed implants were unreturned, the above-mentioned values show no changes. Assuming 5% (10%) of unreturned nonosseointegrated implants, the average success rate of Zeramex T decreases from 96.7% to 96.6% (96.4%) and of Zeralock from 98.5% to 98.4% (98.4%), respectively. The success rate of Zeramex Plus implants remains unchanged at 99.4%.
CONCLUSION: The results of this study imply that two-piece zirconia implants show competitive success rates, improved from >96.7% to >98.5% over three product generations.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26840270     DOI: 10.1097/ID.0000000000000365

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  3 in total

1.  Osseointegration of a novel injection molded 2-piece ceramic dental implant: a study in minipigs.

Authors:  Geninho Thomé; Rebecca Sandgren; Sergio Bernardes; Larissa Trojan; Nils Warfving; Benjamin Bellón; Benjamin E Pippenger
Journal:  Clin Oral Investig       Date:  2020-09-10       Impact factor: 3.573

2.  Clinical and radiographic success of injection-molded 2-piece zirconia implants submitted to immediate loading: A 12-month report of two cases.

Authors:  Geninho Thomé; Jean Uhlendorf; Camila Pereira Vianna; Waleska Caldas; Sergio Rocha Bernardes; Larissa Carvalho Trojan
Journal:  Clin Case Rep       Date:  2021-12-04

3.  Zirconia versus Titanium Implants: 8-Year Follow-Up in a Patient Cohort Contrasted with Histological Evidence from a Preclinical Animal Model.

Authors:  Warwick J Duncan; Sunyoung Ma; Allauddin Siddiqi; Reham B Osman
Journal:  Materials (Basel)       Date:  2022-08-02       Impact factor: 3.748