Literature DB >> 26838431

A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection.

F Di Nardo1, L Anfossi2, C Giovannoli1, C Passini1, V V Goftman3, I Y Goryacheva4, C Baggiani1.   

Abstract

A fluorescent immunochromatographic strip test (ICST) based on the use of Quantum Dots (QD) was developed and applied to detect fumonisins in maize samples. A limit of detection for fumonisin B1 of 2.8 µg L(-1) was achieved, with an analytical working range of 3-350 µg L(-1), corresponding to 30-3500 µg kg(-1) in maize flour samples, according with the extraction procedure. The time required to perform the analysis was 22 min, including sample preparation. Recovery values in the range from 91.4% to 105.4% with coefficients of variation not exceeding 5% were obtained for fortified and naturally contaminated maize flour samples. To evaluate the possible improvements due to the use of QD for ICST technology, we performed a direct comparison of the proposed QD-ICST to a gold nanoparticles- and a chemiluminescent-ICST previously developed for fumonisins detection, in which the same immunoreagents were employed.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fumonisin B1; Immunoassay; Immunochromatography; Maize; Quantum Dot

Mesh:

Substances:

Year:  2015        PMID: 26838431     DOI: 10.1016/j.talanta.2015.12.072

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  12 in total

1.  Aptamer-based fluorometric lateral flow assay for creatine kinase MB.

Authors:  Jing Zhang; Xuefei Lv; Wei Feng; Xiaoqiong Li; Kunjie Li; Yulin Deng
Journal:  Mikrochim Acta       Date:  2018-07-07       Impact factor: 5.833

2.  A lateral flow immunoassay for straightforward determination of fumonisin mycotoxins based on the quenching of the fluorescence of CdSe/ZnS quantum dots by gold and silver nanoparticles.

Authors:  Laura Anfossi; Fabio Di Nardo; Simone Cavalera; Cristina Giovannoli; Giulia Spano; Elena S Speranskaya; Irina Y Goryacheva; Claudio Baggiani
Journal:  Mikrochim Acta       Date:  2018-01-10       Impact factor: 5.833

3.  Development of a smartphone-based rapid dual fluorescent diagnostic system for the simultaneous detection of influenza A and H5 subtype in avian influenza A-infected patients.

Authors:  Seon-Ju Yeo; Homan Kang; Tung Duy Dao; Bui Thi Cuc; Anh Thi Viet Nguyen; Trinh Thi Thuy Tien; Nguyen Le Khanh Hang; Hoang Vu Mai Phuong; Le Thi Thanh; Le Quynh Mai; Yoonhyuk Rah; Kyoungsik Yu; Ho-Joon Shin; Chom-Kyu Chong; Hak Soo Choi; Hyun Park
Journal:  Theranostics       Date:  2018-11-29       Impact factor: 11.556

4.  A Gold Growth-Based Plasmonic ELISA for the Sensitive Detection of Fumonisin B1 in Maize.

Authors:  Shengnan Zhan; Lingyan Zheng; Yaofeng Zhou; Kesheng Wu; Hong Duan; Xiaolin Huang; Yonghua Xiong
Journal:  Toxins (Basel)       Date:  2019-06-05       Impact factor: 4.546

5.  Design and Quantitative Analysis of Cancer Detection System Based on Fluorescence Immune Analysis.

Authors:  Lei Shao; Longyu Zhang; Shilin Li; Pengyuan Zhang
Journal:  J Healthc Eng       Date:  2019-12-24       Impact factor: 2.682

6.  A quantum dot fluorescent microsphere based immunochromatographic strip for detection of brucellosis.

Authors:  Yufang Kong; Huiyu Wang; Shaoqiang Wu; Jizhou Lv; Lin Mei; Huifang Zhou; Xiangmei Lin; Xueqing Han
Journal:  BMC Vet Res       Date:  2021-01-23       Impact factor: 2.741

7.  A fluorescence immunoassay based on CdTe : Zn/ZnS quantum dots for the rapid detection of bacteria, taking Delftia tsuruhatensis CM'13 as an example.

Authors:  Yao Ruan; Huanhuan Xu; Jinlu Yu; Qian Chen; Lihong Gu; Ailing Guo
Journal:  RSC Adv       Date:  2019-12-11       Impact factor: 3.361

8.  Simultaneous Lateral Flow Immunoassay for Multi-Class Chemical Contaminants in Maize and Peanut with One-Stop Sample Preparation.

Authors:  Du Wang; Jianguo Zhu; Zhaowei Zhang; Qi Zhang; Wen Zhang; Li Yu; Jun Jiang; Xiaomei Chen; Xuefang Wang; Peiwu Li
Journal:  Toxins (Basel)       Date:  2019-01-20       Impact factor: 4.546

9.  Dual lateral flow optical/chemiluminescence immunosensors for the rapid detection of salivary and serum IgA in patients with COVID-19 disease.

Authors:  Aldo Roda; Simone Cavalera; Fabio Di Nardo; Donato Calabria; Sergio Rosati; Patrizia Simoni; Barbara Colitti; Claudio Baggiani; Matilde Roda; Laura Anfossi
Journal:  Biosens Bioelectron       Date:  2020-10-26       Impact factor: 10.618

Review 10.  The Existing Methods and Novel Approaches in Mycotoxins' Detection.

Authors:  Edyta Janik; Marcin Niemcewicz; Marcin Podogrocki; Michal Ceremuga; Leslaw Gorniak; Maksymilian Stela; Michal Bijak
Journal:  Molecules       Date:  2021-06-29       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.