A torso model comparison of temperature preservation devices for use in the prehospital environment.

Michele Zasa1, Neil Flowers2, David Zideman2, Timothy J Hodgetts2, Tim Harris3.   

Abstract

BACKGROUND: Hypothermia is an independent predictor of increased morbidity and mortality in patients with trauma. Several strategies and products have been developed to minimise patients' heat loss in the prehospital arena, but there is little evidence to inform the clinician concerning their effectiveness.
METHODS: We used a human torso model consisting of two 5.5-litre fluid bags to simultaneously compare four passive (space blanket, bubble wrap, Blizzard blanket, ambulance blanket) and one active (Ready-Heat II blanket) temperature preservation products. A torso model without any temperature preservation device provided a control. For each test, the torso models were warmed to 37°C and left outdoors. Core temperatures were recorded every 10 min for 1 h in total; tests were repeated 10 times.
RESULTS: A significant difference in temperature was detected among groups at 30 and 60 min (F (1.29, 10.30)=103.58, p<0.001 and F (1.64, 14.78)=163.28, p<0.001, respectively). Mean temperature reductions (95% CI) after 1 h of environmental exposure were the following: 11.6 (10.3 to 12.9) °C in control group, 4.5 (3.9 to 5.1) °C in space blanket group, 3.6 (3 to 4.3) °C in bubble-wrap group, 2.1 (1.7 to 2.5) °C in Blizzard blanket group, 6.1 (5.8 to 6.5) °C in ambulance blanket group and 1.1 (0.7 to 1.6) °C in Ready-Heat II blanket group.
CONCLUSIONS: In this study, using a torso model based on two 5 L dialysate bags we found the Ready-Heat II heating blanket and Blizzard blanket were associated with lower rates of heat loss after 60 min environmental exposure than the other devices tested. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

Entities:  

Keywords:  Trauma; emergency ambulance systems; environmental medicine, hypothermia; hypothermia; prehospital care

Mesh:

Year:  2016        PMID: 26838037     DOI: 10.1136/emermed-2015-204769

Source DB:  PubMed          Journal:  Emerg Med J        ISSN: 1472-0205            Impact factor:   2.740


  5 in total

Review 1.  Accidental hypothermia-an update : The content of this review is endorsed by the International Commission for Mountain Emergency Medicine (ICAR MEDCOM).

Authors:  Peter Paal; Les Gordon; Giacomo Strapazzon; Monika Brodmann Maeder; Gabriel Putzer; Beat Walpoth; Michael Wanscher; Doug Brown; Michael Holzer; Gregor Broessner; Hermann Brugger
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-09-15       Impact factor: 2.953

2.  Measurements of rates of cooling of a manikin insulated with different mountain rescue casualty bags.

Authors:  Christopher Press; Christopher Duffy; Jonathan Williams; Ben Cooper; Neil Chapman
Journal:  Extrem Physiol Med       Date:  2017-04-20

Review 3.  Multiple trauma management in mountain environments - a scoping review : Evidence based guidelines of the International Commission for Mountain Emergency Medicine (ICAR MedCom). Intended for physicians and other advanced life support personnel.

Authors:  G Sumann; D Moens; B Brink; M Brodmann Maeder; M Greene; M Jacob; P Koirala; K Zafren; M Ayala; M Musi; K Oshiro; A Sheets; G Strapazzon; D Macias; P Paal
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2020-12-14       Impact factor: 2.953

Review 4.  Rescue Blankets as Multifunctional Rescue Equipment in Alpine and Wilderness Emergencies-A Narrative Review and Clinical Implications.

Authors:  Bernd Wallner; Hannah Salchner; Markus Isser; Thomas Schachner; Franz J Wiedermann; Wolfgang Lederer
Journal:  Int J Environ Res Public Health       Date:  2022-10-05       Impact factor: 4.614

Review 5.  Rescue blankets as multifunctional rescue equipment in alpine and wilderness emergencies: a commentary.

Authors:  Bernd Wallner; Hannah Salchner; Markus Isser; Thomas Schachner; Franz J Wiedermann; Wolfgang Lederer
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2022-03-10       Impact factor: 2.953

  5 in total