Literature DB >> 26836070

Real-time 3D digital image correlation method and its application in human pulse monitoring.

Xinxing Shao, Xiangjun Dai, Zhenning Chen, Xiaoyuan He.   

Abstract

In industrial measurements and online monitoring, full-field and high-efficiency deformation analysis has been increasingly important and highly demanded in recent years. In this paper, a fast three-dimensional digital image correlation (3D-DIC) method was proposed to implement real-time measurement. Two improvements were suggested to accelerate the computation speed without sacrificing the accuracy. First, an efficient inverse compositional Gauss-Newton (IC-GN) algorithm was developed to avoid redundant computation. Moreover, a seed point-based parallel method was extended for 3D-DIC to achieve parallel computation and faster convergence speed. The detailed process of the real-time measurement using the proposed method was also introduced. Benefiting from the efficient IC-GN algorithm and parallel processing software we developed, full-field, real-time 3D deformation monitoring was realized at a frame rate of 10 frames/s with resolution of 5000 points per frame. For validation, the displacement field of a four-point bending beam was determined by the real-time 3D-DIC. As an application, the real-time human pulse diagnosis was also performed based on the presented technique. Experimental results verify that the proposed real-time 3D-DIC is practicable and effective for traditional Chinese medicine.

Entities:  

Year:  2016        PMID: 26836070     DOI: 10.1364/AO.55.000696

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  5 in total

1.  Soft tissue elastography via shearing interferometry.

Authors:  Dominic Buchta; Hüseyin Serbes; Daniel Claus; Giancarlo Pedrini; Wolfgang Osten
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-02

2.  Three-dimensional shape and deformation measurement on complex structure parts.

Authors:  Zhoujie Wu; Wenbo Guo; Zhengdong Chen; Haoran Wang; Xunren Li; Qican Zhang
Journal:  Sci Rep       Date:  2022-05-11       Impact factor: 4.996

3.  Comparative Analysis of Warp Function for Digital Image Correlation-Based Accurate Single-Shot 3D Shape Measurement.

Authors:  Xiao Yang; Xiaobo Chen; Juntong Xi
Journal:  Sensors (Basel)       Date:  2018-04-16       Impact factor: 3.576

4.  Precise Detection of Wrist Pulse Using Digital Speckle Pattern Interferometry.

Authors:  Hengfei Zhang; Sijin Wu; Weixian Li; Yonghong Wang; Mingli Dong; Lianxiang Yang
Journal:  Evid Based Complement Alternat Med       Date:  2018-06-07       Impact factor: 2.629

5.  Efficient Background Segmentation and Seed Point Generation for a Single-Shot Stereo System.

Authors:  Xiao Yang; Xiaobo Chen; Juntong Xi
Journal:  Sensors (Basel)       Date:  2017-12-01       Impact factor: 3.576

  5 in total