Literature DB >> 2683351

Strength characteristics and failure modes of suture patterns in severed goat tendons.

G J Pjanowski1, L E Stein, T A Turner.   

Abstract

The load-to-gap formation, maximum load, gap present at maximum load, and failure mode were compared among four suture patterns: Bunnell-Mayer, modified Kessler, Mason-Allen, and simple interrupted. Sixty-four goat tendons were sutured with 2-0 monofilament polypropylene in one of the patterns and distracted at 92 cm/min with an electrohydraulic materials testing system. All tests were filmed at 40 frames/sec with an intermittent pin registered camera. The load-to-gap formation was not significantly different among the Bunnell (13.3 +/- 1.5 newtons [N]), Kessler (12.8 +/- 1.3 N), and simple interrupted (11.7 +/- 1.7 N) patterns. The Mason-Allen pattern was significantly different )8.2 +/- 0.5 N). The Bunnell-Mayer had the highest mean maximum load to failure (43.0 +/- 1.6 N) followed by the modified Kessler (34.1 +/- 1.9 N). There was no difference between the Mason-Allen (22.9 +/- 1.4 N) and simple interrupted (21.2 +/- 1.4 N). All of the patterns permitted at least a 1 cm gap to form when the maximum load was applied. The Bunnell pattern caused severe constriction of the tendon and failed by suture material disruption. The modified Kessler caused some focal constriction, but the suture material pulled out before breaking and sliced the tendon in the process. The Mason-Allen and the simple interrupted patterns sliced the tendon as the suture pulled out of the tendon.

Entities:  

Mesh:

Year:  1989        PMID: 2683351     DOI: 10.1111/j.1532-950x.1989.tb01095.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  4 in total

1.  Surgical technique: when to arthroscopically repair the torn posterior cruciate ligament.

Authors:  Gregory S Difelice; Micah Lissy; Paul Haynes
Journal:  Clin Orthop Relat Res       Date:  2012-03       Impact factor: 4.176

2.  Comparison of Clinical, Biomechanical, and Histopathological Effects of Various Suture Techniques on Repair of Tendon Rupture by using Autograft.

Authors:  Celal Şahin Ermutlu; Vedat Baran
Journal:  J Vet Res       Date:  2017-12-06       Impact factor: 1.744

3.  Triceps brachii tendon injury in four Pomeranians.

Authors:  Ryosuke Echigo; Atsushi Fujita; Ryohei Nishimura; Manabu Mochizuki
Journal:  J Vet Med Sci       Date:  2018-03-22       Impact factor: 1.267

4.  Suturing Achilles tendon and mesh simultaneously in augmented repair resists gap formation foremost: an experimental study.

Authors:  William McCartney; Ciprian Ober; Maria Benito; Bryan MacDonald
Journal:  J Orthop Surg Res       Date:  2019-10-24       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.