| Literature DB >> 26832819 |
Jian Chen1, Wenyan Han1, Rui Su2, Jie Chen1, Wenhui Zong1, Yue Wang1, Weichao Wang1, Guanghui Cheng1, Lailiang Ou1, Yaoting Yu1.
Abstract
Strong base anion exchange resin (e.g., BL-300) is currently used to eliminate bilirubin from blood in clinical hemoperfusion. However, there is a potential weakness of the resin to remove heparin and activation of coagulation. To overcome this weakness, we prepared a novel non-ionic macroporous polystyrene adsorbent (SZ-9) with rich mesopores and high surface area by suspension polymerization. Test results indicated that SZ-9 performed better adsorption capacity for bilirubin than BL-300. In addition, better blood compatibility was observed during whole blood hemoperfusion. Therefore, adsorbent SZ-9 might be an efficient alternative to anion exchange resin for the removal of bilirubin in hemoperfusion.Entities:
Keywords: Blood purification; liver failure; non-ionic adsorbents; polystyrenel serum toxins
Mesh:
Substances:
Year: 2016 PMID: 26832819 DOI: 10.3109/21691401.2016.1138494
Source DB: PubMed Journal: Artif Cells Nanomed Biotechnol ISSN: 2169-1401 Impact factor: 5.678