Literature DB >> 26832779

Electronic central bearing point as registration method in individuals with and without temporomandibular disorders.

Antje Zorn1, Ingrid Peroz2.   

Abstract

OBJECTIVES: The aim of this study was to examine different central bearing point methods in patients with and without temporomandibular disorders (TMD) by an experienced and unexperienced examiner.
MATERIAL AND METHODS: The 20 fully dentulous subjects were screened for TMD based on the Research Diagnostic Criteria for TMD and distinguished into functional impaired and functional healthy groups. The mandibular relationship was recorded by an electronic central bearing tracing device (IPR-System, IPR GmbH, Oldenburg, Germany) with an integrated pressure sensor. Three bite registration methods were performed using this device: initial neuromuscular position, final neuromuscular position after dynamic sequences with the intraoral pin (=neuromuscular deprogramming), and centric relation guided manually by an experienced and an unexperienced examiner.
RESULTS: The neuromuscular positions before and after neuromuscular deprogramming were not significantly different (paired t test as a group comparison test: transverse: p = 0.369; sagittal: p = 0.486). Both positions were significantly anterior in comparison to the manually guided centric relation (paired t test as a group comparison test: p < 0.0001). The neuromuscular positions before and after deprogramming tend to have high scattering values.
CONCLUSION: By means of the central bearing point method, the manually guided centric relation is the one which is sufficiently reproducible. It seems doubtful to take the significant anterior neuromuscular position for a definite reconstruction. CLINICAL RELEVANCE: Using the central bearing point method, the manually guided centric relation should be preferred, whereas the neuromuscular position should not be used for definite reconstructions.

Entities:  

Keywords:  Centric bearing device; Centric relation; Maxillomandibular relationship; TMD

Mesh:

Year:  2016        PMID: 26832779     DOI: 10.1007/s00784-016-1735-1

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  19 in total

Review 1.  The effect of a deprogrammer on the position of the terminal transverse horizontal axis of the mandible.

Authors:  K E Kinderknecht; G K Wong; E J Billy; S H Li
Journal:  J Prosthet Dent       Date:  1992-07       Impact factor: 3.426

2.  The influence of different registration techniques on condyle displacement and electromyographic activity in stomatognathically healthy subjects: a prospective study.

Authors:  Sabine S Linsen; Helmut Stark; Azadeh Samai
Journal:  J Prosthet Dent       Date:  2012-01       Impact factor: 3.426

3.  Precision of jaw-closing movements for different jaw gaps.

Authors:  Daniel Hellmann; Georg Becker; Nikolaos N Giannakopoulos; Lydia Eberhard; Christopher Fingerhut; Peter Rammelsberg; Hans J Schindler
Journal:  Eur J Oral Sci       Date:  2013-11-12       Impact factor: 2.612

4.  [Studies of the position of the mandible in patients with a complete dentition].

Authors:  R Trage
Journal:  Dtsch Zahnarztl Z       Date:  1977-02

5.  The prevalence and magnitude of mandibular displacement in a survey population.

Authors:  C E Rieder
Journal:  J Prosthet Dent       Date:  1978-03       Impact factor: 3.426

6.  Replicability of chinpoint-guidance and anterior programmer for recording centric relation.

Authors:  I Shafagh; R Amirloo
Journal:  J Prosthet Dent       Date:  1979-10       Impact factor: 3.426

7.  "Myo-Monitor centric": an evaluation.

Authors:  J C Remien; M Ash
Journal:  J Prosthet Dent       Date:  1974-02       Impact factor: 3.426

8.  The centric position: replacement and character.

Authors:  F V Celenza
Journal:  J Prosthet Dent       Date:  1973-10       Impact factor: 3.426

9.  Variation of retruded and muscular position of mandible under different recording conditions.

Authors:  M Helkimo; B Ingervall; G E Carlsson
Journal:  Acta Odontol Scand       Date:  1971-10       Impact factor: 2.331

10.  [Comparative studies on various registration methods].

Authors:  L Hupfauf
Journal:  Dtsch Zahnarztl Z       Date:  1971-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.