Literature DB >> 26832312

Assessment of mitral valve morphology using three-dimensional echocardiography. Feasibility and reference values.

G Menciotti1, M Borgarelli2, M Aherne2, J Häggström3, I Ljungvall3, S M Lahmers2, J A Abbott2.   

Abstract

OBJECTIVES: To evaluate the feasibility of real time transthoracic three-dimensional echocardiography (RT3DE) for evaluation of normal canine mitral valves (MVs), and to provide reference values for this technique. ANIMALS: Forty-three cardiologically healthy, not sedated dogs.
METHODS: Transthoracic RT3DE mitral datasets were acquired during two consecutive 6-month periods. The datasets were analyzed using commercially available software. An MV model was drawn using a semiautomated procedure and MV variables were obtained and calculated. The ratio between annulus height and commissural diameter was used as an index of the annulus' saddle-shaped non-planarity. After evaluation of associations between measured variables and body size, the datasets were used to generate reference intervals. Coefficients of variation (CVs), variance components, and repeatability coefficients were calculated for the evaluation of intra-observer, inter-observer, and day-to-day variability.
RESULTS: Datasets could be analyzed in 34 of 43 (79%) dogs. 68 percent of datasets obtained during the first 6-month period could be analyzed and 90% obtained during the second period could be analyzed. An allometric relationship was identified for most MV variables. The MV annulus appeared elliptical and saddle-shaped. Inter- and intra-observer CVs were less than 20%. Coefficient of variation greater than 20% was calculated for the inter-day variation for some variables. Operator and observer were primarily responsible for the variation of most of the variables.
CONCLUSIONS: Evaluation of canine mitral valves by transthoracic RT3DE is feasible. Canine MVs of healthy dogs analyzed using RT3DE are elliptical and saddle-shaped. Reference intervals for the measured MV variables are proposed.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Canine; Diagnostic; Heart; Imaging

Mesh:

Year:  2016        PMID: 26832312     DOI: 10.1016/j.jvc.2015.11.002

Source DB:  PubMed          Journal:  J Vet Cardiol        ISSN: 1760-2734            Impact factor:   1.701


  2 in total

1.  Comparison of the mitral valve morphologies of Cavalier King Charles Spaniels and dogs of other breeds using 3D transthoracic echocardiography.

Authors:  Giulio Menciotti; Michele Borgarelli; Michael Aherne; Paula Camacho; Jens Häggström; Ingrid Ljungvall; Sunshine M Lahmers; Jonathan A Abbott
Journal:  J Vet Intern Med       Date:  2018-09-20       Impact factor: 3.333

Review 2.  Review of Diagnostic and Therapeutic Approach to Canine Myxomatous Mitral Valve Disease.

Authors:  Giulio Menciotti; Michele Borgarelli
Journal:  Vet Sci       Date:  2017-09-26
  2 in total