Literature DB >> 26830616

Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality.

Chen-Jiang Wu1, Qing Wang2, Jing Zhang3, Xiao-Ning Wang4, Xi-Sheng Liu5, Yu-Dong Zhang6, Hai-Bin Shi7.   

Abstract

OBJECTIVE: The purpose of this study was to compare the image quality of readout-segmented echo-planar imaging (RS-EPI) and that of standard single-shot echo-planar imaging (SS-EPI) in the kidney in a rat model.
MATERIALS AND METHODS: Twelve Wistar rats undergoing MRI examinations were imaged with two diffusion-weighted (DW) imaging protocols: a standard SS-EPI and a new RS-EPI protocol, both with a 1.0 × 1.0 × 3.0 mm voxel. The two groups of diffusion-weighted images were independently scored on geometric distortion, image blurring, signal dropout, and the overall image quality by two radiologists. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) were measured on both sequences. Inter-rater agreement (IRA) was evaluated by Fleiss kappa (κ) and inter-class correlation coefficient (ICC) statistics. Comparisons of image qualities were made by Wilcoxon signed-rank test and paired-sample t test.
RESULTS: Both RS-EPI and SS-EPI had good IRAs in scoring image qualities (κ = 0.607-0.833) and measuring renal ADCs (ICC = 0.828-0.945). Compared to SS-EPI, RS-EPI produced less geometric distortion (median score 1.5 versus 2.5, p < 0.0001), less image blurring (1.75 versus 2.0, p = 0.0003), less signal dropout (1.0 versus 3.0, p = 0.0001), and a lower score in overall image artifacts (4.25 versus 7.25; p < 0.0001). RS-EPI had higher SNR of renal DW images than SS-EPI (p < 0.001). The intra-variability of ADCs in cortex, outer medulla, and inner medulla ranged from 9.6% to 11.1% (Pearson correlation coefficient ρ = 0.675-0.729; p < 0.001) between the two protocols.
CONCLUSION: We showed that for DWI of the kidney at 1.0 × 1.0 × 3.0 mm(3) voxel sizes, the new protocol provided better image quality than standard SS-EPI protocol.

Entities:  

Keywords:  Diffusion-weighted imaging; Kidney; Magnetic resonance imaging; Readout-segmented echo-planar imaging; Single-shot echo-planar imaging

Mesh:

Year:  2016        PMID: 26830616     DOI: 10.1007/s00261-015-0615-5

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  5 in total

1.  Comparison between readout-segmented and single-shot echo-planar imaging in the evaluation of cervical cancer staging.

Authors:  Weiliang Qian; Qian Chen; Zhongshuai Zhang; Hong Wang; Jibin Zhang; Jianming Xu
Journal:  Br J Radiol       Date:  2018-11-01       Impact factor: 3.039

2.  Apparent diffusion coefficient (ADC) histogram analysis: differentiation of benign from malignant parotid gland tumors using readout-segmented diffusion-weighted imaging.

Authors:  Zanxia Zhang; Chengru Song; Yong Zhang; Baohong Wen; Jinxia Zhu; Jingliang Cheng
Journal:  Dentomaxillofac Radiol       Date:  2019-07-09       Impact factor: 2.419

3.  Applicability of readout-segmented echoplanar diffusion weighted imaging for prostate MRI.

Authors:  Susanne Hellms; Marcel Gutberlet; Matti Joonas Peperhove; Stefanie Pertschy; Christoph Henkenberens; Inga Peters; Frank Wacker; Katja Derlin
Journal:  Medicine (Baltimore)       Date:  2019-07       Impact factor: 1.817

4.  High b value DWI in evaluation of the hyperacute cerebral ischemia at 3T: A comparative study in an embolic canine stroke model.

Authors:  Qiguang Cheng; Xiaoquan Xu; Qingquan Zu; Shanshan Lu; Jing Yu; Xinglong Liu; Bin Wang; Haibin Shi; Gaojun Teng; Sheng Liu
Journal:  Exp Ther Med       Date:  2016-05-27       Impact factor: 2.447

5.  Bladder cancer: detection and image quality compared among iShim, RESOLVE, and ss-EPI diffusion-weighted MR imaging with high b value at 3.0 T MRI.

Authors:  Hongyi Li; Lin Liu; Qinglei Shi; Alto Stemmer; Hong Zeng; Yi Li; Mengchao Zhang
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  5 in total