Literature DB >> 26829879

Toward a Boron-Doped Ultrananocrystalline Diamond Electrode-Based Dielectrophoretic Preconcentrator.

Wenli Zhang1, Adarsh D Radadia1.   

Abstract

This paper presents results on immunobeads-based isolation of rare bacteria and their capture at a boron-doped ultrananocrystalline diamond (BD-UNCD) electrode in a microfluidic dielectrophoretic preconcentrator. We systematically vary the bead surface chemistry and the BD-UNCD surface chemistry and apply dielectrophoresis to improve the specific and the nonspecific capture of bacteria or beads. Immunobeads were synthesized by conjugating antibodies to epoxy-/sulfate, aldehyde-/sulfate, or carboxylate-modified beads with or without poly(ethylene glycol) (PEG) coimmobilization. The carboxylate-modified beads with PEG provided the highest capture efficiency (∼65%) and selectivity (∼95%) in isolating live Escherichia coli O157:H7 from cultures containing 1000 E. coli O157:H7 colony-forming units (cfu)/mL, or ∼500 E. coli O157:H7 and ∼500 E. coli K12 cfu/mL. Higher specificity was achieved with the addition of PEG to the antibody-functionalized bead surface, highest with epoxy-/sulfate beads (85-86%), followed by carboxylate-modified beads (76-78%) and aldehyde-/sulfate beads (74-76%). The bare BD-UNCD electrodes of the preconcentrator successfully withstood 240 kV/m for 100 min that was required for the microfluidic dielectrophoresis of 1 mL of sample. As expected, the application of dielectrophoresis increased the specific and the nonspecific capture of immunobeads at the BD-UNCD electrodes; however, the capture specificity remained unaltered. The addition of PEG to the antibody-functionalized BD-UNCD surface had little effect on the specificity in immunobeads capture. These results warrant the fabrication of electrical biosensors with BD-UNCD so that dielectrophoretic preconcentration can be performed directly at the biosensing electrodes.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26829879     DOI: 10.1021/acs.analchem.5b03227

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  A nanofilter for fluidic devices by pillar-assisted self-assembly microparticles.

Authors:  Tamer AbdelFatah; Mahsa Jalali; Sara Mahshid
Journal:  Biomicrofluidics       Date:  2018-11-19       Impact factor: 2.800

Review 2.  Review: Microbial analysis in dielectrophoretic microfluidic systems.

Authors:  Renny E Fernandez; Ali Rohani; Vahid Farmehini; Nathan S Swami
Journal:  Anal Chim Acta       Date:  2017-03-06       Impact factor: 6.558

Review 3.  A review of polystyrene bead manipulation by dielectrophoresis.

Authors:  Qiaoying Chen; Yong J Yuan
Journal:  RSC Adv       Date:  2019-02-08       Impact factor: 4.036

4.  Few-Flakes Reduced Graphene Oxide Sensors for Organic Vapors with a High Signal-to-Noise Ratio.

Authors:  Nowzesh Hasan; Wenli Zhang; Adarsh D Radadia
Journal:  Nanomaterials (Basel)       Date:  2017-10-21       Impact factor: 5.076

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.