Literature DB >> 26829764

Quantifying the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building.

Zheming Tong1, Yujiao Chen2, Ali Malkawi2, Gary Adamkiewicz3, John D Spengler3.   

Abstract

Improper natural ventilation practices may deteriorate indoor air quality when in close proximity to roadways, although the intention is often to reduce energy consumption. In this study, we employed a CFD-based air quality model to quantify the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building. Our study found that the building envelope restricts dispersion and dilution of particulate matter. The indoor concentration in the baseline condition located 10m away from the roadway is roughly 16-21% greater than that at the edge of the roadway. The indoor flow recirculation creates a well-mixed zone with little variation in fine particle concentration (i.e., 253nm). For ultrafine particles (<100nm), a noticeable decrease in particle concentrations indoors with increasing distance from the road is observed due to Brownian and turbulent diffusion. In addition, the indoor concentration strongly depends on the distance between the roadway and building, particle size, wind condition, and window size and location. A break-even point is observed at D'~2.1 (normalized distance from the roadway by the width of the road). The indoor particle concentration is greater than that at the highway where D'<2.1, and vice versa. For new building planning, the distance from the roadway and the ambient wind condition need to be considered at the early design stage whereas the size and location of the window openings, the interior layout, and the placement of fresh air intakes are important to the indoor air quality of existing buildings adjacent to roadways.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Keywords:  Computational fluid dynamics (CFD); I/O ratio; Indoor air quality; Natural ventilation; Particulate matter; Ultrafine particles (UFPs)

Mesh:

Substances:

Year:  2016        PMID: 26829764     DOI: 10.1016/j.envint.2016.01.016

Source DB:  PubMed          Journal:  Environ Int        ISSN: 0160-4120            Impact factor:   9.621


  13 in total

Review 1.  A review of AirQ Models and their applications for forecasting the air pollution health outcomes.

Authors:  Gea Oliveri Conti; Behzad Heibati; Itai Kloog; Maria Fiore; Margherita Ferrante
Journal:  Environ Sci Pollut Res Int       Date:  2017-01-04       Impact factor: 4.223

2.  Effectiveness of a portable air cleaner in removing aerosol particles in homes close to highways.

Authors:  Jennie Cox; Kelechi Isiugo; Patrick Ryan; Sergey A Grinshpun; Michael Yermakov; Colleen Desmond; Roman Jandarov; Stephen Vesper; James Ross; Steven Chillrud; Karen Dannemiller; Tiina Reponen
Journal:  Indoor Air       Date:  2018-09-17       Impact factor: 5.770

Review 3.  Supporting sustainability initiatives through biometeorology education and training.

Authors:  Michael J Allen; Jennifer Vanos; David M Hondula; Daniel J Vecellio; David Knight; Hamed Mehdipoor; Rebekah Lucas; Chris Fuhrmann; Hanna Lokys; Angela Lees; Sheila Tavares Nascimento; Andrew C W Leung; David R Perkins
Journal:  Int J Biometeorol       Date:  2017-07-19       Impact factor: 3.787

4.  Simulations of the impacts of building height layout on air quality in natural-ventilated rooms around street canyons.

Authors:  Fang Yang; Ke Zhong; Yonghang Chen; Yanming Kang
Journal:  Environ Sci Pollut Res Int       Date:  2017-08-30       Impact factor: 4.223

5.  Effectiveness of indoor air purification intervention in improving cardiovascular health: A systematic review and meta-analysis of randomized controlled trials.

Authors:  Xi Xia; Ka Hung Chan; Kin Bong Hubert Lam; Hong Qiu; Zhiyuan Li; Steve Hung Lam Yim; Kin-Fai Ho
Journal:  Sci Total Environ       Date:  2021-05-25       Impact factor: 7.963

6.  Case Study of Airborne Pathogen Dispersion Patterns in Emergency Departments with Different Ventilation and Partition Conditions.

Authors:  Chang Heon Cheong; Seonhye Lee
Journal:  Int J Environ Res Public Health       Date:  2018-03-13       Impact factor: 3.390

7.  Assessment of Home-Based and Mobility-Based Exposure to Black Carbon in an Urban Environment: A Pilot Study.

Authors:  Max Gerrit Adam; Phuong Thi Minh Tran; David Kok Wai Cheong; Sitaraman Chandra Sekhar; Kwok Wai Tham; Rajasekhar Balasubramanian
Journal:  Int J Environ Res Public Health       Date:  2021-05-10       Impact factor: 3.390

8.  Characterizing particulate polycyclic aromatic hydrocarbon emissions from diesel vehicles using a portable emissions measurement system.

Authors:  Xuan Zheng; Ye Wu; Shaojun Zhang; Jingnan Hu; K Max Zhang; Zhenhua Li; Liqiang He; Jiming Hao
Journal:  Sci Rep       Date:  2017-08-30       Impact factor: 4.379

9.  Impact of Outdoor Air Pollution on Indoor Air Quality in Low-Income Homes during Wildfire Seasons.

Authors:  Prateek M Shrestha; Jamie L Humphrey; Elizabeth J Carlton; John L Adgate; Kelsey E Barton; Elisabeth D Root; Shelly L Miller
Journal:  Int J Environ Res Public Health       Date:  2019-09-21       Impact factor: 3.390

10.  Dispersion Characteristics of Hazardous Gas and Exposure Risk Assessment in a Multiroom Building Environment.

Authors:  Xiaoping Liu; Zhen Peng; Xianghua Liu; Rui Zhou
Journal:  Int J Environ Res Public Health       Date:  2019-12-27       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.