Literature DB >> 26826549

Development and validation of a CE-MS method for the targeted assessment of amino acids in urine.

Karina T Rodrigues1,2, Djalila Mekahli3,4, Marina F M Tavares2, Ann Van Schepdael1.   

Abstract

A CE-ESI-MS method was developed and validated for the separation and quantitative analysis of amino acids (AA) in urine. Experimental parameters related to the CE-MS interface, BGE, and mass spectrometer (MS) settings were optimized providing a good separation of 27 AA, including the isomers L-leucine, L-isoleucine, and L-alloisoleucine, in less than 30 min. The sheath liquid was composed by 0.50% formic acid in 60% (v,v) methanol-water delivered at a flow rate of 5 μL/min. The BGE consisted of 0.80 mol/L formic acid at pH 1.96 and 15% methanol. A pH stacking procedure was implemented to enhance sensitivity (a 12.5% NH4 OH solution was injected at 0.5 psi/9 s prior to samples injected at 0.6 psi/20 s). The proposed method was validated according to FDA and ICH protocols exhibiting acceptable parameters. Analytical curves presented coefficients of determination from 0.996 to 0.9997 (with large F statistics and low p-values). LODs and quantification ranged from 0.63 to 29 μmol/L and from 1.9 to 86 μmol/L, respectively. Practical repeatability was obtained for all AA with coefficients of variation better than 0.55% CV (migration time) and 1.7% CV (peak area ratios; methionine sulfone as internal standard). Recoveries of AA in spiked urine ranged from 92.0 to 123% with few exceptions. Moreover, a successful quantification of AA in pooled control and test urine samples, which compose a vesicoureteral reflux cohort, was achieved showing the potential applicability of the proposed method for targeted metabolomics studies using CE-ESI-MS with an Ion Trap as mass analyzer.
© 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Amino acids; CE-ESI-MS; Targeted metabolomics; Urine

Mesh:

Substances:

Year:  2016        PMID: 26826549     DOI: 10.1002/elps.201500534

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  6 in total

1.  A reliable LC-MS/MS method for the quantification of natural amino acids in mouse plasma: Method validation and application to a study on amino acid dynamics during hepatocellular carcinoma progression.

Authors:  Zhenzhen Liu; Mei-Juan Tu; Chao Zhang; Joseph L Jilek; Qian-Yu Zhang; Ai-Ming Yu
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2019-06-02       Impact factor: 3.205

Review 2.  Current state of the art for enhancing urine biomarker discovery.

Authors:  Michael Harpole; Justin Davis; Virginia Espina
Journal:  Expert Rev Proteomics       Date:  2016-06       Impact factor: 3.940

Review 3.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

Review 4.  Exploring the human microbiome from multiple perspectives: factors altering its composition and function.

Authors:  David Rojo; Celia Méndez-García; Beata Anna Raczkowska; Rafael Bargiela; Andrés Moya; Manuel Ferrer; Coral Barbas
Journal:  FEMS Microbiol Rev       Date:  2017-07-01       Impact factor: 16.408

5.  Capillary Electrophoresis: Trends and Recent Advances.

Authors:  Robert L C Voeten; Iro K Ventouri; Rob Haselberg; Govert W Somsen
Journal:  Anal Chem       Date:  2018-01-18       Impact factor: 6.986

6.  Profiling of Amino Acids in Urine Samples of Patients Suffering from Inflammatory Bowel Disease by Capillary Electrophoresis-Mass Spectrometry.

Authors:  Juraj Piestansky; Dominika Olesova; Jaroslav Galba; Katarina Marakova; Vojtech Parrak; Peter Secnik; Peter Secnik; Branislav Kovacech; Andrej Kovac; Zuzana Zelinkova; Peter Mikus
Journal:  Molecules       Date:  2019-09-14       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.