Literature DB >> 26822349

Bias and precision analysis of diffusional kurtosis imaging for different acquisition schemes.

Tim Sprenger1,2, Jonathan I Sperl2, Brice Fernandez3, Vladimir Golkov1,4, Ines Eidner5, Philipp G Sämann5, Michael Czisch5, Ek T Tan6, Christopher J Hardy6, Luca Marinelli6, Axel Haase1, Marion I Menzel2.   

Abstract

PURPOSE: Diffusional kurtosis imaging (DKI) is an approach to characterizing the non-Gaussian fraction of water diffusion in biological tissue. However, DKI is highly susceptible to the low signal-to-noise ratio of diffusion-weighted images, causing low precision and a significant bias due to Rician noise distribution. Here, we evaluate precision and bias using weighted linear least squares fitting of different acquisition schemes including several multishell schemes, a diffusion spectrum imaging (DSI) scheme, as well as a compressed sensing reconstruction of undersampled DSI scheme.
METHODS: Monte Carlo simulations were performed to study the three-dimensional distribution of the apparent kurtosis coefficient (AKC). Experimental data were acquired from one healthy volunteer with multiple repetitions, using the same acquisition schemes as for the simulations.
RESULTS: The angular distribution of the bias and precision were very inhomogeneous. While axial kurtosis was significantly overestimated, radial kurtosis was underestimated. The precision of radial kurtosis was up to 10-fold lower than axial kurtosis.
CONCLUSION: The noise bias behavior of DKI is highly complex and can cause overestimation as well as underestimation of the AKC even within one voxel. The acquisition scheme with three shells, suggested by Poot et al, provided overall the best performance. Magn Reson Med 76:1684-1696, 2016.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  compressed sensing; diffusion spectrum imaging; kurtosis; q-space; undersampling

Mesh:

Year:  2016        PMID: 26822349     DOI: 10.1002/mrm.26008

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Peripheral nerve stimulation limits of a high amplitude and slew rate magnetic field gradient coil for neuroimaging.

Authors:  Ek T Tan; Yihe Hua; Eric W Fiveland; Mark E Vermilyea; Joseph E Piel; Keith J Park; Vincent B Ho; Thomas K F Foo
Journal:  Magn Reson Med       Date:  2019-08-06       Impact factor: 4.668

2.  Compressed Sensing Diffusion Spectrum Imaging for Accelerated Diffusion Microstructure MRI in Long-Term Population Imaging.

Authors:  Alexandra Tobisch; Rüdiger Stirnberg; Robbert L Harms; Thomas Schultz; Alard Roebroeck; Monique M B Breteler; Tony Stöcker
Journal:  Front Neurosci       Date:  2018-09-24       Impact factor: 4.677

3.  Diffusion kurtosis and quantitative susceptibility mapping MRI are sensitive to structural abnormalities in amyotrophic lateral sclerosis.

Authors:  Thomas Welton; Jerome J Maller; R Marc Lebel; Ek T Tan; Dominic B Rowe; Stuart M Grieve
Journal:  Neuroimage Clin       Date:  2019-07-22       Impact factor: 4.881

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.