Post-Formation Shrinkage and Stabilization of Microfluidic Bubbles in Lipid Solution.

Roger Shih1, Abraham P Lee1.   

Abstract

Medical ultrasound imaging often employs ultrasound contrast agents (UCAs), injectable microbubbles stabilized by shells or membranes. In tissue, the compressible gas cores can strongly scatter acoustic signals, resonate, and emit harmonics. However, bubbles generated by conventional methods have nonuniform sizes, reducing the fraction that resonates with a given transducer. Microfluidic flow-focusing is an alternative production method which generates highly monodisperse bubbles with uniform constituents, enabling more-efficient contrast enhancement than current UCAs. Production size is tunable by adjusting gas pressure and solution flow rate, but solution effects on downstream stable size and lifetime have not been closely examined. This study therefore investigated several solution parameters, including the DSPC/DSPE-PEG2000 lipid ratio, concentration, viscosity, and preparation temperature to determine their effects on stabilization. It was found that bubble lifetime roughly correlated with stable size, which in turn was strongly influenced by primary-lipid-to-emulsifier ratio, analogous to its effects on conventional bubble yield and Langmuir-trough compressibility in existing studies. Raising DSPE-PEG2000 fraction in solution reduced bubble surface area in proportion to its reduction of lipid packing density at low compression in literature. In addition, the surface area was found to increase proportionately with lipid concentration above 2.1 mM. However, viscosities above or below 2.3-3.3 mPa·s seemed to reduce bubble size. Finally, lipid preparation at room temperature led to smaller bubbles compared to preparation near or above the primary lipid's phase transition point. Understanding these effects will further improve on postformation control over microfluidic bubble production, and facilitate size-tuning for optimal contrast enhancement.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26820229     DOI: 10.1021/acs.langmuir.5b03948

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  2 in total

1.  The development of mechanically formed stable nanobubbles intended for sonoporation-mediated gene transfection.

Authors:  Rodi Abdalkader; Shigeru Kawakami; Johan Unga; Yuriko Higuchi; Ryo Suzuki; Kazuo Maruyama; Fumiyoshi Yamashita; Mitsuru Hashida
Journal:  Drug Deliv       Date:  2017-11       Impact factor: 6.419

2.  Focal areas of increased lipid concentration on the coating of microbubbles during short tone-burst ultrasound insonification.

Authors:  Klazina Kooiman; Tom van Rooij; Bin Qin; Frits Mastik; Hendrik J Vos; Michel Versluis; Alexander L Klibanov; Nico de Jong; Flordeliza S Villanueva; Xucai Chen
Journal:  PLoS One       Date:  2017-07-07       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.