Literature DB >> 26818471

PET iterative reconstruction incorporating an efficient positron range correction method.

Ottavia Bertolli1, Afroditi Eleftheriou2, Matteo Cecchetti3, Niccolò Camarlinghi3, Nicola Belcari3, Charalampos Tsoumpas4.   

Abstract

Positron range is one of the main physical effects limiting the spatial resolution of positron emission tomography (PET) images. If positrons travel inside a magnetic field, for instance inside a nuclear magnetic resonance (MR) tomograph, the mean range will be smaller but still significant. In this investigation we examined a method to correct for the positron range effect in iterative image reconstruction by including tissue-specific kernels in the forward projection operation. The correction method was implemented within STIR library (Software for Tomographic Image Reconstruction). In order to obtain the positron annihilation distribution of various radioactive isotopes in water and lung tissue, simulations were performed with the Monte Carlo package GATE [Jan et al. 2004 [1]] simulating different magnetic field intensities (0 T, 3 T, 9.5 T and 11 T) along the axial scanner direction. The positron range kernels were obtained for (68)Ga in water and lung tissue for 0 T and 3 T magnetic field voxellizing the annihilation coordinates into a three-dimensional matrix. The proposed method was evaluated using simulations of material-variant and material-invariant positron range corrections for the HYPERImage preclinical PET-MR scanner. The use of the correction resulted in sharper active region boundary definition, albeit with noise enhancement, and in the recovery of the true activity mean value of the hot regions. Moreover, in the case where a magnetic field is present, the correction accounts for the non-isotropy of the positron range effect, resulting in the recovery of resolution along the axial plane.
Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Iterative reconstruction; PET; PET/MR; Positron range; STIR

Mesh:

Year:  2016        PMID: 26818471     DOI: 10.1016/j.ejmp.2015.11.005

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  10 in total

Review 1.  3D/4D Reconstruction and Quantitative Total Body Imaging.

Authors:  Jinyi Qi; Samuel Matej; Guobao Wang; Xuezhu Zhang
Journal:  PET Clin       Date:  2021-01

Review 2.  Advances in Preclinical PET.

Authors:  Stephen S Adler; Jurgen Seidel; Peter L Choyke
Journal:  Semin Nucl Med       Date:  2022-03-18       Impact factor: 4.802

3.  Monte Carlo Simulations of the GE Signa PET/MR for Different Radioisotopes.

Authors:  Paulo R R V Caribé; Stefaan Vandenberghe; André Diogo; David Pérez-Benito; Nikos Efthimiou; Charlotte Thyssen; Yves D'Asseler; Michel Koole
Journal:  Front Physiol       Date:  2020-09-15       Impact factor: 4.566

4.  Quantitative performance and optimal regularization parameter in block sequential regularized expectation maximization reconstructions in clinical 68Ga-PSMA PET/MR.

Authors:  Edwin E G W Ter Voert; Urs J Muehlematter; Gaspar Delso; Daniele A Pizzuto; Julian Müller; Hannes W Nagel; Irene A Burger
Journal:  EJNMMI Res       Date:  2018-07-27       Impact factor: 3.138

5.  Impact of time of flight and point spread function on quantitative parameters of lung lesions in 18F-FDG PET/CT.

Authors:  Kemin Huang; Yanlin Feng; Weitang Liang; Lin Li
Journal:  BMC Med Imaging       Date:  2021-11-13       Impact factor: 1.930

6.  Implementation of a Spatially-Variant and Tissue-Dependent Positron Range Correction for PET/CT Imaging.

Authors:  Hunor Kertész; Thomas Beyer; Vladimir Panin; Walter Jentzen; Jacobo Cal-Gonzalez; Alexander Berger; Laszlo Papp; Peter L Kench; Deepak Bharkhada; Jorge Cabello; Maurizio Conti; Ivo Rausch
Journal:  Front Physiol       Date:  2022-03-08       Impact factor: 4.566

7.  Positron range in combination with point-spread-function correction: an evaluation of different implementations for [124I]-PET imaging.

Authors:  Hunor Kertész; Maurizio Conti; Vladimir Panin; Jorge Cabello; Deepak Bharkhada; Thomas Beyer; Laszlo Papp; Walter Jentzen; Jacobo Cal-Gonzalez; Joaquín L Herraiz; Alejandro López-Montes; Ivo Rausch
Journal:  EJNMMI Phys       Date:  2022-08-19

8.  Feasibility of positron range correction in 82-Rubidium cardiac PET/CT.

Authors:  Malte Jensen; Simon Bentsen; Andreas Clemmensen; Jacob Kildevang Jensen; Johanne Madsen; Jonas Rossing; Anna Laier; Philip Hasbak; Andreas Kjaer; Rasmus Sejersten Ripa
Journal:  EJNMMI Phys       Date:  2022-07-30

9.  Comparison of image quality and spatial resolution between 18F, 68Ga, and 64Cu phantom measurements using a digital Biograph Vision PET/CT.

Authors:  Anja Braune; Liane Oehme; Robert Freudenberg; Frank Hofheinz; Jörg van den Hoff; Jörg Kotzerke; Sebastian Hoberück
Journal:  EJNMMI Phys       Date:  2022-09-05

10.  SMART (SiMulAtion and ReconsTruction) PET: an efficient PET simulation-reconstruction tool.

Authors:  Elisabeth Pfaehler; Johan R De Jong; Rudi A J O Dierckx; Floris H P van Velden; Ronald Boellaard
Journal:  EJNMMI Phys       Date:  2018-09-18
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.