Literature DB >> 26818289

Sutureless Microsurgical Anastomosis Using an Optimized Thermoreversible Intravascular Poloxamer Stent.

Christopher R Davis1, C Travis Rappleye, Peter A Than, Melanie Rodrigues, Michael W Findlay, Sarah N Bishop, Arnetha J Whitmore, Zeshaan N Maan, Rory B McGoldrick, Adriaan O Grobbelaar, Geoffrey C Gurtner.   

Abstract

BACKGROUND: Sutureless microvascular anastomosis has great translational potential to simplify microvascular surgery, shorten operative times, and improve clinical outcomes. The authors developed a transient thermoreversible microvascular stent using a poloxamer to maintain vessel lumen patency before application of commercially available adhesives to seal the anastomosis instead of sutures. Despite technical success, human application necessitates bovine serum albumin removal from existing formulations; rapid poloxamer transition between states; and increased stiffness for reliable, reproducible, and precise microvascular approximation.
METHODS: Two commercially available poloxamers were used in this study (P407 and P188). After removing bovine serum albumin, each poloxamer was tested at varying concentrations either alone or in combination to determine the optimal preparation for sutureless microvascular anastomosis. Transition temperature and formulation stiffness were tested in vitro by rheometry, with the most promising combinations tested in an established in vivo model.
RESULTS: Increasing poloxamer concentration resulted in an increase in stiffness and decrease in transition temperature. Pure P188 without bovine serum albumin, dissolved in phosphate-buffered saline to a 45% concentration, demonstrated desirable rheologic behavior, with precise gel transition and increased gel stiffness compared with our previous formulation of 17% P407 (96 kPa versus 10 kPa). These characteristics were optimal for microsurgical intravascular use, offering surgical precision and control between liquid and solid states, depending on the surgically controlled local temperature.
CONCLUSIONS: Use of 45% P188 without bovine serum albumin demonstrated optimal rheologic and translational properties as a microvascular stent for sutureless anastomosis. Rapid transition, increased stiffness, and safety profile demonstrate safe translational application for human clinical trials.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26818289     DOI: 10.1097/01.prs.0000475774.37267.3f

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  2 in total

1.  Reduction of Anastomotic Time Through the Use of Cyanoacrylate in Microvascular Procedures.

Authors:  Alex V Orădan; George C Dindelegan; Ramona C Vinaşi; Maximilian V Muntean; Maximilian G Dindelegan; Liviu Chiriac; Victor Volovici
Journal:  Plast Surg (Oakv)       Date:  2021-05-28       Impact factor: 0.558

Review 2.  The History and Innovations of Blood Vessel Anastomosis.

Authors:  William R Moritz; Shreya Raman; Sydney Pessin; Cameron Martin; Xiaowei Li; Amanda Westman; Justin M Sacks
Journal:  Bioengineering (Basel)       Date:  2022-02-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.