Literature DB >> 26817482

Association between light-to-dark changes in angle width and iris parameters in light, dark and changes from light-to-dark conditions.

Roland Y Lee1, Shuai-Chun Lin2, Rebecca I Chen3, Diego T Barbosa4, Shan C Lin2.   

Abstract

BACKGROUND/AIMS: To evaluate the association between light-to-dark changes in angle width parameters and iris parameters in light, dark and changes from light-to-dark conditions.
METHODS: In this prospective, cross-sectional study, anterior segment optical coherence tomography images, obtained under light and dark conditions, were analysed to determine angle opening distance measured at 500 μm from the scleral spur (AOD500), trabecular-iris space area at 500 μm from the scleral spur (TISA500), iris thickness measured at 750 μm from the scleral spur (IT750), iris thickness measured at 2000 μm from the scleral spur (IT2000), iris area (IArea) and pupil diameter (PD). Multivariable linear mixed-effect regression models were used to evaluate the association between light-to-dark changes in angle width parameters (AOD500, TISA500) and iris parameters (IT750, IT2000, IArea, PD) in light, dark and changes from light-to-dark conditions.
RESULTS: 534 eyes from 314 non-glaucomatous subjects were analysed. IT750, IT2000, IArea and PD in light conditions were significantly associated with light-to-dark changes in AOD500 (p<0.05). IT750, IT2000 and IArea in light conditions were significantly associated with light-to-dark changes in TISA500 (p<0.05). IT750 in dark conditions was significantly associated with light-to-dark changes in AOD500 and TISA500 (p<0.05). Light-to-dark changes in IT2000, IArea and PD were significantly associated with light-to-dark changes in AOD500 (p<0.05). Light-to-dark changes in IArea were significantly associated with light-to-dark changes in TISA500 (p<0.05).
CONCLUSIONS: Evaluation of iris parameters in light, dark and changes from light-to-dark conditions demonstrated that IT750, IT2000, IArea and PD in light conditions are significant predictors of light-to-dark changes in angle width. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

Entities:  

Keywords:  Glaucoma; Imaging; Iris

Mesh:

Year:  2016        PMID: 26817482     DOI: 10.1136/bjophthalmol-2015-307393

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  3 in total

1.  Identification of peripheral anterior synechia with anterior segment optical coherence tomography.

Authors:  Yingying Dai; Shaodan Zhang; Meixiao Shen; Zi Jin; Yuheng Zhou; Shuling Ye; Chenhong Bao; Dexi Zhu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-05-11       Impact factor: 3.117

2.  The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography.

Authors:  Sakari Nakamine; Hiroshi Sakai; Yoshikuni Arakaki; Michiko Yonahara; Tadayoshi Kaiya
Journal:  Jpn J Ophthalmol       Date:  2017-11-01       Impact factor: 2.447

3.  Identification of Peripheral Anterior Synechia by Corneal Deformation Using Air-Puff Dynamic Anterior Segment Optical Coherence Tomography.

Authors:  Shuling Ye; Chenhong Bao; Yulei Chen; Meixiao Shen; Fan Lu; Shaodan Zhang; Dexi Zhu
Journal:  Front Bioeng Biotechnol       Date:  2022-04-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.