Literature DB >> 26815394

Implant removal in children.

P P Schmittenbecher1.   

Abstract

PURPOSE: Implant removal in children is still a standard procedure. Implants may disturb function, and some theoretical long-term risks like growth disturbance, foreign body reaction, chronic infection and corrosion are used as arguments for removal. Implant migration or interference with any other orthopaedic treatment over the later course of life is also a matter of debate. On the other hand, the difficulty in removing single implants as well as possible perioperative complications has induced discussion about the retention of implants in childhood.
METHODS: The current procedures are exposed and the available literature on implant removal in children reviewed.
RESULTS: Actually, a clear recommendation does not exist. The current line of action still includes routine removal, as it is preferred by some authors, whereas others argue for a selective procedure. K-wires as well as intramedullary nails are usually removed because the ends may interfere with the surrounding tissue. Screws and plates can be retained if there are no local problems. The removal of external fixators is non-controversial.
CONCLUSIONS: Benefits have to outweigh the risks and complications in the individual case and the procedure should not require a more extensive procedure than insertion. It has to be an individual decision in view of the lack of evidence to support routine removal as well as to refute it.

Entities:  

Keywords:  Child; Complication; Implant removal; Implant retainment

Year:  2013        PMID: 26815394     DOI: 10.1007/s00068-013-0286-2

Source DB:  PubMed          Journal:  Eur J Trauma Emerg Surg        ISSN: 1863-9933            Impact factor:   3.693


  27 in total

Review 1.  Primary total replacement of the dysplastic hip.

Authors:  F S Haddad; B A Masri; D S Garbuz; C P Duncan
Journal:  Instr Course Lect       Date:  2000

2.  Removal of deep extremity implants in children.

Authors:  J R Davids; C Hydorn; C Dillingham; J W Hardin; L I Pugh
Journal:  J Bone Joint Surg Br       Date:  2010-07

3.  Tips of the trade #15. Removal of hardware prior to total hip replacement.

Authors:  H U Cameron
Journal:  Orthop Rev       Date:  1989-08

4.  Removal of orthopedic implants in children: morbidity and postoperative radiologic changes.

Authors:  M E Lovell; C S Galasko; N B Wright
Journal:  J Pediatr Orthop B       Date:  1999-04       Impact factor: 1.041

5.  Implant-related fractures in children: a 15-year review.

Authors:  Amit Jain; Gurkan Erkula; Arabella I Leet; Michael C Ain; Paul D Sponseller
Journal:  J Pediatr Orthop       Date:  2012 Jul-Aug       Impact factor: 2.324

6.  Acute complications associated with removal of flexible intramedullary femoral rods placed for pediatric femoral shaft fractures.

Authors:  Jeffrey A Levy; David A Podeszwa; Geof Lebus; Christine A Ho; Robert L Wimberly
Journal:  J Pediatr Orthop       Date:  2013-01       Impact factor: 2.324

Review 7.  Surfaces to control tissue adhesion for osteosynthesis with metal implants: in vitro and in vivo studies to bring solutions to the patient.

Authors:  Jessica S Hayes; R Geoff Richards
Journal:  Expert Rev Med Devices       Date:  2010-01       Impact factor: 3.166

8.  Retention of flexible intramedullary nails following treatment of pediatric femur fractures.

Authors:  Saam Morshed; Marcie Humphrey; Luis A Corrales; Meredith Millett; Scott A Hoffinger
Journal:  Arch Orthop Trauma Surg       Date:  2007-01-20       Impact factor: 3.067

9.  Metal removal in a pediatric population: benign procedure or necessary evil?

Authors:  T P Schmalzried; T J Grogan; P A Neumeier; F J Dorey
Journal:  J Pediatr Orthop       Date:  1991 Jan-Feb       Impact factor: 2.324

10.  Implant removal after submuscular plating for pediatric femur fractures.

Authors:  Olivia Pate; Daniel Hedequist; Natalie Leong; Timothy Hresko
Journal:  J Pediatr Orthop       Date:  2009 Oct-Nov       Impact factor: 2.324

View more
  6 in total

1.  Inpatient orthopaedic hardware removal in children: A cross-Sectional study.

Authors:  Alexandre Boulos; Steven F DeFroda; Justin E Kleiner; Nathan Thomas; Joseph A Gil; Aristides I Cruz
Journal:  J Clin Orthop Trauma       Date:  2017-07-01

2.  Plate Fixation for Unstable Displaced Distal Radius Fractures in Children.

Authors:  Jeroen C van Egmond; Caroline A Selles; Berry I Cleffken; Gert R Roukema; Kees H van der Vlies; Niels W L Schep
Journal:  J Wrist Surg       Date:  2019-05-09

3.  Use of Resorbable Magnesium Screws in Children: Systematic Review of the Literature and Short-Term Follow-Up From Our Series.

Authors:  Marco Baldini; Valentino Coppa; Danya Falcioni; Elisa Senigagliesi; Mario Marinelli; Antonio Pompilio Gigante
Journal:  J Child Orthop       Date:  2022-04-05       Impact factor: 1.917

4.  Indications of implant removal: A study of 83 cases.

Authors:  Muhammad Haseeb; Muhammad Farooq Butt; Tariq Altaf; Khalid Muzaffar; Anil Gupta; Aleena Jallu
Journal:  Int J Health Sci (Qassim)       Date:  2017 Jan-Mar

5.  Bioresorbable implants vs. Kirschner-wires in the treatment of severely displaced distal paediatric radius and forearm fractures - a retrospective multicentre study.

Authors:  Marcell Varga; Gergő Józsa; Dániel Hanna; Máté Tóth; Bence Hajnal; Zsófia Krupa; Tamás Kassai
Journal:  BMC Musculoskelet Disord       Date:  2022-04-18       Impact factor: 2.562

6.  Implant removal associated complications after ESIN osteosynthesis in pediatric fractures.

Authors:  Justus Lieber; Markus Dietzel; Simon Scherer; Jürgen F Schäfer; Hans-Joachim Kirschner; Jörg Fuchs
Journal:  Eur J Trauma Emerg Surg       Date:  2021-08-02       Impact factor: 2.374

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.