Literature DB >> 26813242

Implant-retained prostheses: ball vs. conus attachments - A randomized controlled clinical trial.

Sandy Cepa1, Beatrice Koller2, Benedikt Christopher Spies3, Susanne Stampf4, Ralf-Joachim Kohal3.   

Abstract

OBJECTIVE: To evaluate implant survival, peri-implant tissue conditions, prosthodontic maintenance requirements and patient satisfaction of two differently retained implant-supported mandibular overdentures (IOD) after the 3 years of observation.
MATERIALS AND METHODS: Twenty-five patients with edentulous mandibles received two implants each. Twelve patients were randomly selected to receive ball attachments, whereas 13 patients received prefabricated coni. Implant survival, peri-implant parameters (modified Plaque Index, Bleeding on Probing, modified Gingival Index, probing depth and marginal bone loss) and patient satisfaction were assessed. Additionally, prosthodontic maintenance was monitored. Clinical and radiographic follow-ups were performed 1, 2 and 3 years after prosthetic delivery. The Kaplan-Meier method was used to calculate complication rates.
RESULTS: After a mean observation period of 29.6 months, an implant survival rate of 100% could be observed. There were no significant differences in the peri-implant parameters. During the observation period, six patients with conus attachment refused to further participate in follow-ups due to dissatisfaction with their treatment and had to be regarded as dropouts. Based on the Kaplan-Meier method, inacceptable retention was calculated for 80% and 75% of the patients in the ball and the conus groups, respectively. Patient satisfaction was 64% for the ball- and 100% for the conus-retained IODs, the latter only respecting five of initially 13 patients.
CONCLUSION: The evaluated treatment method revealed high implant survival rates, but the prosthetic reconstruction required intensive maintenance. Therefore, a trend toward the reduced patient satisfaction was observed, and the promoted economy of the evaluated attachment systems should be questioned. For the conical attachment, the recommendation of the manufacturer is to use four interforaminal implants to support a removable prostheses.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  SynCone; ball attachment; dental implants; implant-retained mandibular overdentures; randomized controlled clinical trial

Mesh:

Year:  2016        PMID: 26813242     DOI: 10.1111/clr.12779

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

Review 1.  Unsplinted Attachments and Patient-Reported Outcome Measures (PROMs) in 2-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Pravinkumar G Patil; Liang Lin Seow; Ting Jing Kweh; Smita Nimbalkar
Journal:  Int J Dent       Date:  2022-05-24

2.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

Review 3.  Prosthodontic maintenance and peri-implant tissue conditions for telescopic attachment-retained mandibular implant overdenture: Systematic review and meta-analysis of randomized clinical trials.

Authors:  Ahmed Mohamed Keshk; Ahmed Yaseen Alqutaibi; Radhwan S Algabri; Mostafa S Swedan; Amal Kaddah
Journal:  Eur J Dent       Date:  2017 Oct-Dec

4.  Oral Health-Related Quality of Life in Single Implant Mandibular Overdenture Retained by CM LOC versus Ball Attachment: A Randomized Controlled Trial.

Authors:  Marwa AbdelAal; Ahmed Fayyad; Nora Sheta; Nouran AbdelNabi; Mahmoud Mokhtar ELFar
Journal:  Open Access Maced J Med Sci       Date:  2019-10-11

Review 5.  A systematic review and meta-analysis of the attachments used in implant-supported overdentures.

Authors:  Sachin Haribhau Chaware; Smruti Tushar Thakkar
Journal:  J Indian Prosthodont Soc       Date:  2020-07-17

6.  Clinical outcomes of implant-retained mandibular overdentures using the bar and magnetic attachment systems: an up to 5-year retrospective study.

Authors:  Huan Zhou; Yang Jiao; Chu-Fan Ma; Chao Wang; San-Jun Zhao; Min Tian; Franklin R Tay; Ji-Hua Chen
Journal:  Ann Transl Med       Date:  2020-11

Review 7.  Mandibular implant-supported overdenture: A systematic review and meta-analysis for optimum selection of attachment system.

Authors:  Priyanka Vaibhav Sutariya; Hitendra Mohanlal Shah; Surbhi Dipakbhai Patel; Hemil Hitesh Upadhyay; Mansoorkhan Rafikahmed Pathan; Rutu Paresh Shah
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

8.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.