Literature DB >> 26808286

Preliminary Experience with the GORE(®) EXCLUDER(®) Iliac Branch Endoprosthesis for Common Iliac Aneurysm Endovascular Treatment.

Antoine Millon1, Nellie Della Schiava2, Matthieu Arsicot2, Alberic De Lambert3, Patrick Feugier2, Jean Luc Magne3, Patrick Lermusiaux2.   

Abstract

BACKGROUND: The aim of this study is to assess the safety and the short-term results of endovascular treatment of common iliac artery (CIA) aneurysms using the new GORE EXCLUDER iliac branch endoprosthesis (IBE) device.
METHODS: The study is a retrospective with prospective follow-up nonrandomized, single-arm evaluation. Patients with a CIA aneurysm (diameter >30 mm) extending to the iliac bifurcation underwent endovascular treatment with the Gore IBE. Anatomic and procedural data were collected. Computed tomography angiography (CTA) was performed within the 30 days after the procedure and every 6 month. Thirty-day and at least 6-months outcomes were investigated.
RESULTS: From February 2014 to December 2014, 10 male patients with aneurysmal CIA (mean age 75 years old) underwent consecutive endovascular treatment with the Gore IBE. The CIA aneurysm (mean diameter 43.2 mm, range 32-49) treated with the Gore IBE was associated with an abdominal aortic aneurysm (AAA) in 5 patients. One patient had a previous AAA open repair. CIA aneurysm was bilateral in 5 patients. Preliminary procedure of internal iliac artery embolization was performed in 3 patients. Technical success rate of the Gore IBE implantation was 100% with a median fluoroscopy time of 35 min (range 12-64, ±16) and median contrast load of 150 mL (range 100-250, ±45). No perioperative complications were observed. Median length of stay was 4 days (range 3-7, ±2). One aortic type Ia endoleak was observed on the postoperative CT scan requiring an aortic extension at day 3. Branch patency was observed in all 10 patients at 1 month and 9 patients at 6 month. All CIA aneurysms were excluded without type Ib or type III endoleak.
CONCLUSIONS: The technical success and short-term results demonstrate encouraging results and clinical benefits of the new GORE EXCLUDER IBE. A longer follow-up is needed to assess midterm and long-term results.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26808286     DOI: 10.1016/j.avsg.2015.12.003

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  5 in total

Review 1.  Endovascular management of iliac aneurysmal disease with hypogastric artery preservation.

Authors:  Brian J Schiro; Ripal T Gandhi; Constantino S Peña; Adam R Geronemus; Alex Powell; James F Benenati
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

2.  Outcomes of Endovascular Repair of Aortoiliac Aneurysms and Analyses of Anatomic Suitability for Internal Iliac Artery Preserving Devices in Japanese Patients.

Authors:  Nathan K Itoga; Naoki Fujimura; Keita Hayashi; Hideaki Obara; Hideyuki Shimizu; Jason T Lee
Journal:  Circ J       Date:  2017-02-02       Impact factor: 2.993

3.  Endovascular repair of bilateral common iliac artery aneurysms using GORE Excluder iliac branch endoprosthesis without aortobi-iliac stent graft conjunction: A case report.

Authors:  Vincenzo Ardita; Alessia Giaquinta; Massimiliano Veroux; Angelo Sanfiorenzo; Carla Virgilio; Giuseppe D'Arrigo; Pierfrancesco Veroux
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.889

4.  Bifurcated unibody aortic endografts can overcome unfavorable aortoiliac anatomy for deployment of bilateral iliac branch endoprostheses.

Authors:  Arash Fereydooni; Christine Deyholos; Robert Botta; Nariman Nezami; Alan Dardik; Naiem Nassiri
Journal:  J Vasc Surg Cases Innov Tech       Date:  2019-05-25

5.  Progressing left-side sciatica revealing a common iliac artery mycotic aneurysm in an elderly patient: A CARE-compliant case report.

Authors:  Tzu-Yen Huang; Chi-Hsiao Yeh; Yao-Chang Wang; Yu-Ting Cheng; Pin-Chao Feng
Journal:  Medicine (Baltimore)       Date:  2020-10-09       Impact factor: 1.817