Literature DB >> 26805703

Differences in the intensity of light-induced fluorescence emitted by resin composites.

Bo-Ra Kim1, Si-Mook Kang2, Gyung-Min Kim3, Baek-Il Kim4.   

Abstract

BACKGROUND: The aims of this study were to compare the intensities of fluorescence emitted by different resin composites as detected using quantitative light-induced fluorescence (QLF) technology, and to compare the fluorescence intensity contrast with the color contrast between a restored composite and the adjacent region of the tooth.
METHODS: Six brands of light-cured resin composites (shade A2) were investigated. The composites were used to prepare composite discs, and fill holes that had been prepared in extracted human teeth. White-light and fluorescence images of all specimens were obtained using a fluorescence camera based on QLF technology (QLF-D) and converted into 8-bit grayscale images. The fluorescence intensity of the discs as well as the fluorescence intensity contrast and the color contrast between the composite restoration and adjacent tooth region were calculated as grayscale levels.
RESULTS: The grayscale levels for the composite discs differed significantly with the brand (p<0.001): DenFil (10.84±0.35, mean±SD), Filtek Z350 (58.28±1.37), Premisa (156.94±1.58), Grandio (177.20±0.81), Charisma (207.05±0.77), and Gradia direct posterior (211.52±1.66). The difference in grayscale levels between a resin restoration and the adjacent tooth was significantly greater in fluorescence images for each brand than in white-light images, except for the Filtek Z350 (p<0.05). However, the Filtek Z350 restoration was distinguishable from the adjacent tooth in a fluorescence image.
CONCLUSIONS: The intensities of fluorescence detected from the resin composites varied. The differences between the composite and adjacent tooth were greater for the fluorescence intensity contrast than for the colors observed in the white-light images.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Detection; Fluorescence; Quantitative light-induced fluorescence technology; Resin composites

Mesh:

Substances:

Year:  2016        PMID: 26805703     DOI: 10.1016/j.pdpdt.2016.01.005

Source DB:  PubMed          Journal:  Photodiagnosis Photodyn Ther        ISSN: 1572-1000            Impact factor:   3.631


  2 in total

1.  Fluorescence intensities of composite resins on photo images.

Authors:  Ioannis Brokos; Minos Stavridakis; Panos Lagouvardos; Ivo Krejci
Journal:  Odontology       Date:  2021-02-03       Impact factor: 2.634

2.  In vitro evaluation of composite resin fluorescence after natural aging.

Authors:  Talissa-Mayer Garrido; Lidiane-Vizioli-de Castro Hoshino; Ronaldo Hirata; Francielle Sato; Antonio-Medina Neto; Victor-Hugo-Fazoli Guidini; Raquel-Sano-Suga Terada
Journal:  J Clin Exp Dent       Date:  2020-05-01