Evaluation of a novel automated volumetric flow cytometer for absolute CD4+ T lymphocyte quantitation.

Morgane Gossez1,2, Christophe Malcus1, Julie Demaret1,2, John Frater3, Françoise Poitevin-Later1, Guillaume Monneret1,2.   

Abstract

BACKGROUND: Bead-based single platform cytometry technology (SPT) is the gold standard when performing CD4 absolute counting. However, it presents drawbacks as precision depends on various critical steps (for example, pipetting methodology, overtime stability of beads, stability of fluidics, regular recalibration…) and thus requires skilled operators. The fully automated volumetric SPT AQUIOS CL (Beckman Coulter) has recently emerged as an alternative with no need of beads. It may help improving results standardisation and fulfilling requirements for certification (ISO 15189). In this study, we assessed SPT AQUIOS CL performances in accordance to requirements for ISO 15189 accreditation.
METHODS: We evaluated repeatability and reproducibility (precision), bias (trueness), uncertainty (total error), range limits (linearity, quantification, detection limits), and inter-reagent/inter-sample contaminations in enumerating CD4+ T-cells. Concomitantly, we compared AQUIOS CL CD4+ T-cell values with the results obtained with our routine bead-based SPT (that is, FC500 Beckman Coulter, bead-based SPT), on blood samples from 148 patients representative of clinical laboratory routine workload.
RESULTS: Every result (repeatability, reproducibility, trueness, total error) was below the acceptable thresholds proposed in international recommendations. Contamination results and range limits (linearity, quantification, and detection limits) were all found perfectly suitable to routine analysis. The comparison between AQUIOS CL and FC500 exhibited excellent correlation and agreement (Pearson R = 0.99, P < 0.001; Lin's concordance correlation coefficient: Lin ρc  = 0.991, Cb = 0.999), and Bland-Altman analysis did not reveal any systematic error.
CONCLUSIONS: Our results demonstrate that, upon subsequent validation in more routine conditions, the AQUIOS CL could be a suitable tool for clinical flow cytometry laboratories facing accreditation process.
© 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

Entities:  

Keywords:  CD4; AQUIOS; absolute count; flow cytometry

Mesh:

Substances:

Year:  2016        PMID: 26804473     DOI: 10.1002/cyto.b.21360

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.058


  10 in total

1.  Research in morphology and flow cytometry is at the heart of hematology.

Authors:  Marie C Béné; Gina Zini
Journal:  Haematologica       Date:  2017-03       Impact factor: 9.941

2.  Measurement of functional and morphodynamic neutrophil phenotypes in systemic inflammation and sepsis.

Authors:  Rens Zonneveld; G Molema; Frans B Plötz
Journal:  Crit Care       Date:  2016-08-24       Impact factor: 9.097

3.  Performance verification of the new fully automated Aquios flow cytometer PanLeucogate (PLG) platform for CD4-T-lymphocyte enumeration in South Africa.

Authors:  Lindi-Marie Coetzee; Deborah K Glencross
Journal:  PLoS One       Date:  2017-11-03       Impact factor: 3.240

4.  The REAnimation Low Immune Status Markers (REALISM) project: a protocol for broad characterisation and follow-up of injury-induced immunosuppression in intensive care unit (ICU) critically ill patients.

Authors:  Mary-Luz Rol; Fabienne Venet; Thomas Rimmele; Virginie Moucadel; Pierre Cortez; Laurence Quemeneur; David Gardiner; Andrew Griffiths; Alexandre Pachot; Julien Textoris; Guillaume Monneret
Journal:  BMJ Open       Date:  2017-06-21       Impact factor: 2.692

5.  Analysis of peripheral blood lymphocyte subsets in critical patients at ICU admission: A preliminary investigation of their role in the prediction of sepsis during ICU stay.

Authors:  Antonella Frattari; Ennio Polilli; Vanessa Primiterra; Vincenzo Savini; Tamara Ursini; Giancarlo Di Iorio; Giustino Parruti
Journal:  Int J Immunopathol Pharmacol       Date:  2018 Jan-Dec       Impact factor: 3.219

6.  Longitudinal assessment of IFN-I activity and immune profile in critically ill COVID-19 patients with acute respiratory distress syndrome.

Authors:  Fabienne Venet; Martin Cour; Thomas Rimmelé; Sebastien Viel; Hodane Yonis; Remy Coudereau; Camille Amaz; Paul Abraham; Céline Monard; Jean-Sebastien Casalegno; Karen Brengel-Pesce; Anne-Claire Lukaszewicz; Laurent Argaud; Guillaume Monneret
Journal:  Crit Care       Date:  2021-04-12       Impact factor: 9.097

7.  Evaluation and validation of a novel 10-color flow cytometer.

Authors:  Lin Sun; Hui Wu; Baishen Pan; Beili Wang; Wei Guo
Journal:  J Clin Lab Anal       Date:  2021-10-12       Impact factor: 2.352

8.  Abnormal Blood Bacteriome, Gut Dysbiosis, and Progression to Severe Dengue Disease.

Authors:  Wiwat Chancharoenthana; Supitcha Kamolratanakul; Wassawon Ariyanon; Vipa Thanachartwet; Weerapong Phumratanaprapin; Polrat Wilairatana; Asada Leelahavanichkul
Journal:  Front Cell Infect Microbiol       Date:  2022-06-17       Impact factor: 6.073

9.  Polyclonal expansion of TCR Vbeta 21.3+ CD4+ and CD8+ T cells is a hallmark of Multisystem Inflammatory Syndrome in Children.

Authors:  Kenz Le Gouge; Samira Khaldi-Plassart; Rémi Pescarmona; Thierry Walzer; Encarnita Mariotti-Ferrandiz; Etienne Javouhey; Marion Moreews; Anne-Laure Mathieu; Christophe Malcus; Sophia Djebali; Alicia Bellomo; Olivier Dauwalder; Magali Perret; Marine Villard; Emilie Chopin; Isabelle Rouvet; Francois Vandenesh; Céline Dupieux; Robin Pouyau; Sonia Teyssedre; Margaux Guerder; Tiphaine Louazon; Anne Moulin-Zinsch; Marie Duperril; Hugues Patural; Lisa Giovannini-Chami; Aurélie Portefaix; Behrouz Kassai; Fabienne Venet; Guillaume Monneret; Christine Lombard; Hugues Flodrops; Jean-Marie De Guillebon; Fanny Bajolle; Valérie Launay; Paul Bastard; Shen-Ying Zhang; Valérie Dubois; Olivier Thaunat; Jean-Christophe Richard; Mehdi Mezidi; Omran Allatif; Kahina Saker; Marlène Dreux; Laurent Abel; Jean-Laurent Casanova; Jacqueline Marvel; Sophie Trouillet-Assant; David Klatzmann; Alexandre Belot
Journal:  Sci Immunol       Date:  2021-05-25

10.  Automated bedside flow cytometer for mHLA-DR expression measurement: a comparison study with reference protocol.

Authors:  Mehdi Zouiouich; Morgane Gossez; Fabienne Venet; Thomas Rimmelé; Guillaume Monneret
Journal:  Intensive Care Med Exp       Date:  2017-08-30
  10 in total