Literature DB >> 26804044

Formaldehyde and acetaldehyde exposure and risk characterization in California early childhood education environments.

A Bradman1, F Gaspar1, R Castorina1, J Williams2, T Hoang1, P L Jenkins2, T E McKone1,3, R Maddalena3.   

Abstract

Little information is available about air quality in early childhood education (ECE) facilities. We collected single-day air samples in 2010-2011 from 40 ECE facilities serving children ≤6 years old in California and applied new methods to evaluate cancer risk in young children. Formaldehyde and acetaldehyde were detected in 100% of samples. The median (max) indoor formaldehyde and acetaldehyde levels (μg/m3 ) were 17.8 (48.8) and 7.5 (23.3), respectively, and were comparable to other California schools and homes. Formaldehyde and acetaldehyde concentrations were inversely associated with air exchange rates (Pearson r = -0.54 and -0.63, respectively; P < 0.001). The buildings and furnishings were generally >5 years old, suggesting other indoor sources. Formaldehyde levels exceeded California 8-h and chronic Reference Exposure Levels (both 9 μg/m3 ) for non-cancer effects in 87.5% of facilities. Acetaldehyde levels exceeded the U.S. EPA Reference Concentration in 30% of facilities. If reflective of long-term averages, estimated exposures would exceed age-adjusted 'safe harbor levels' based on California's Proposition 65 guidelines (10-5 lifetime cancer risk). Additional research is needed to identify sources of formaldehyde and acetaldehyde and strategies to reduce indoor air levels. The impact of recent California and proposed U.S. EPA regulations to reduce formaldehyde levels in future construction should be assessed.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Acetaldehyde; Air; Child care; Children; Exposure; Formaldehyde

Mesh:

Substances:

Year:  2016        PMID: 26804044     DOI: 10.1111/ina.12283

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  4 in total

1.  Evaluation of air quality in indoor and outdoor environments: Impact of anti-COVID-19 measures.

Authors:  Nicole Ninyà; Laura Vallecillos; Rosa Maria Marcé; Francesc Borrull
Journal:  Sci Total Environ       Date:  2022-05-02       Impact factor: 10.753

2.  Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks.

Authors:  Nan Lin; Marie-Anne Rosemberg; Wei Li; Emily Meza-Wilson; Christopher Godwin; Stuart Batterman
Journal:  Indoor Air       Date:  2020-08-24       Impact factor: 5.770

Review 3.  Re-evaluation of the WHO (2010) formaldehyde indoor air quality guideline for cancer risk assessment.

Authors:  Gunnar Damgård Nielsen; Søren Thor Larsen; Peder Wolkoff
Journal:  Arch Toxicol       Date:  2016-05-21       Impact factor: 5.153

4.  Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools.

Authors:  Juliana P Sá; Pedro T B S Branco; Maria C M Alvim-Ferraz; Fernando G Martins; Sofia I V Sousa
Journal:  Int J Environ Res Public Health       Date:  2017-05-31       Impact factor: 3.390

  4 in total