Literature DB >> 26803221

Environmental forensics in groundwater coupling passive sampling and high resolution mass spectrometry for screening.

Coralie Soulier1, Charlotte Coureau2, Anne Togola2.   

Abstract

One of the difficulties encountered when monitoring groundwater quality is low and fluctuating concentration levels and complex mixtures of micropollutants, including emerging substances or transformation products. Combining passive sampling techniques with analysis by high resolution mass spectrometry (HRMS) should improve environmental metrology. Passive samplers accumulate compounds during exposure, which improves the detection of organic compounds and integrates pollution fluctuations. The Polar Organic Chemical Integrative Sampler (POCIS) were used in this study to sequester polar to semi-polar compounds. The methodology described here improves our knowledge of environmental pollution by highlighting and identifying pertinent compounds to be monitored in groundwater. The advantage of combining these two approaches is demonstrated on two different sites impacted by agricultural and/or urban pollution sources where groundwater was sampled for several months. Grab and passive sampling were done and analyzed by liquid chromatography coupled to a hybrid quadrupole time-of-flight mass spectrometer (LC-QTOF). Various data processing approaches were used (target, suspect and non-target screening). Target screening was based on research from compounds listed in a homemade database and suspect screening used a database compiled using literature data. The non-target screening was done using statistical tools such as principal components analysis (PCA) with direct connections between original chromatograms and ion intensity. Trend plots were used to highlight relevant compounds for their identification. The advantage of using POCIS to improve screening of polar organic compounds was demonstrated. Compounds undetected in water samples were detected with these tools. The subsequent data processing identified sentinel molecules, molecular clusters as compounds never revealed in these sampling sites, and molecular fingerprints. Samples were compared and multidimensional visualization of chemical patterns such as molecular fingerprints and recurrent or specific markers of each site were given.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  High resolution mass spectrometry; Non-target screening; Pocis; Suspect screening; Target screening; Time-of-flight

Mesh:

Substances:

Year:  2016        PMID: 26803221     DOI: 10.1016/j.scitotenv.2016.01.056

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  3 in total

1.  Combination of different chromatographic and sampling modes for high-resolution mass spectrometric screening of organic microcontaminants in water.

Authors:  Verónica Castro; José Benito Quintana; Inmaculada Carpinteiro; Julio Cobas; Nieves Carro; Rafael Cela; Rosario Rodil
Journal:  Anal Bioanal Chem       Date:  2021-02-24       Impact factor: 4.142

2.  Route Determination of Sulfur Mustard Using Nontargeted Chemical Attribution Signature Screening.

Authors:  Karin Höjer Holmgren; Lina Mörén; Linnea Ahlinder; Andreas Larsson; Daniel Wiktelius; Rikard Norlin; Crister Åstot
Journal:  Anal Chem       Date:  2021-03-12       Impact factor: 6.986

Review 3.  Operationalizing the Exposome Using Passive Silicone Samplers.

Authors:  Zoe Coates Fuentes; Yuri Levin Schwartz; Anna R Robuck; Douglas I Walker
Journal:  Curr Pollut Rep       Date:  2022-01-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.