Literature DB >> 26803173

Accuracy in the digital workflow: From data acquisition to the digitally milled cast.

George K Koch1, German O Gallucci2, Sang J Lee3.   

Abstract

STATEMENT OF PROBLEM: The accuracy of digital impressions and the milling of implant crowns greatly influence the clinical outcome of implant restorations.
PURPOSE: The purpose of this in vitro study was to calculate the propagation of error in the process of milling an implant crown.
MATERIAL AND METHODS: Thirty digitally milled casts made directly from a reference model were prepared. The casts were scanned with a laboratory scanner, and 30 standard tesselation language (STL) datasets from each group were imported to inspection software. In each analysis, STL datasets were aligned by a repeated best fit algorithm, and 18 specified contact locations of interest were measured in mean volumetric deviations. The master reference dataset was aligned 30 times to the master reference dataset to determine the software variation. The reference datasets were aligned to the master reference dataset to determine the scanner variation. The milled cast datasets were aligned to the master reference dataset to determine the milling variation. The 18 specified contact locations of interest were pooled by cusps, occlusal ridge/fossae, interproximal contacts, facial/lingual aspect, and implant position. The pooled areas were statistically analyzed by comparing each group with the reference model to investigate the mean volumetric deviations accounting for accuracy and standard deviations for precision.
RESULTS: Software and scanner variation were negligible. Variations in the milled models resulting from software and scanner error exhibited statistical significance (P<.001). Software, scanner, and milling error were shown to propagate through the digital workflow to the milled model.
CONCLUSIONS: The pooled locations may describe the reliability of the milling process as it applies to specific anatomic locations on the tooth.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2016        PMID: 26803173     DOI: 10.1016/j.prosdent.2015.12.004

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  19 in total

1.  Impact of manual control point selection accuracy on automated surface matching of digital dental models.

Authors:  Kathrin Becker; Benedict Wilmes; Chantal Grandjean; Dieter Drescher
Journal:  Clin Oral Investig       Date:  2017-07-05       Impact factor: 3.573

Review 2.  Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review.

Authors:  Ignacio García-Gil; Jorge Cortés-Bretón-Brinkmann; Jaime Jiménez-García; Jesus Peláez-Rico; María-Jesús Suárez-García
Journal:  J Clin Exp Dent       Date:  2020-08-01

3.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

4.  Dimensional accuracy of cone beam CT with varying angulation of the jaw to the X-ray beam.

Authors:  George K Koch; Adam Hamilton; Kelly Wang; Laura Herschdorfer; Kyu Ha Lee; German O Gallucci; Bernard Friedland
Journal:  Dentomaxillofac Radiol       Date:  2018-11-08       Impact factor: 2.419

Review 5.  Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: A systematic review.

Authors:  Sven Mühlemann; Jenni Hjerppe; Christoph H F Hämmerle; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

6.  An Integrated Fully Digital Prosthetic Workflow for the Immediate Full-Arch Restoration of Edentulous Patients-A Case Report.

Authors:  Barbara Sobczak; Piotr Majewski
Journal:  Int J Environ Res Public Health       Date:  2022-03-31       Impact factor: 3.390

Review 7.  The complete digital workflow in fixed prosthodontics: a systematic review.

Authors:  Tim Joda; Fernando Zarone; Marco Ferrari
Journal:  BMC Oral Health       Date:  2017-09-19       Impact factor: 2.757

8.  The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software.

Authors:  Se-Won Park; Yong-Do Choi; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

9.  A study on the machining accuracy of dental digital method focusing on dental inlay.

Authors:  Eun-Jeong Bae; Il-Do Jeong; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2018-08-17       Impact factor: 1.904

10.  Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method.

Authors:  Yoo-Geum Jeong; Wan-Sun Lee; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.