Literature DB >> 26800205

Highly sensitive amperometric biosensor based on electrochemically-reduced graphene oxide-chitosan/hemoglobin nanocomposite for nitromethane determination.

Yunping Wen1, Wei Wen2, Xiuhua Zhang1, Shengfu Wang3.   

Abstract

Nitromethane (CH3NO2) is an important organic chemical raw material with a wide variety of applications as well as one of the most common pollutants. Therefore it is pretty important to establish a simple and sensitive detection method for CH3NO2. In our study, a novel amperometric biosensor for nitromethane (CH3NO2) based on immobilization of electrochemically-reduced graphene oxide (rGO), chitosan (CS) and hemoglobin (Hb) on a glassy carbon electrode (GCE) was constructed. Scanning electron microscopy, infrared spectroscopy and electrochemical methods were used to characterize the Hb-CS/rGO-CS composite film. The effects of scan rate and pH of phosphate buffer on the biosensor have been studied in detail and optimized. Due to the graphene and chitosan nanocomposite, the developed biosensor demonstrating direct electrochemistry with faster electron-transfer rate (6.48s(-1)) and excellent catalytic activity towards CH3NO2. Under optimal conditions, the proposed biosensor exhibited fast amperometric response (<5s) to CH3NO2 with a wide linear range of 5 μM~1.46 mM (R=0.999) and a low detection limit of 1.5 μM (S/N=3). In addition, the biosensor had high selectivity, reproducibility and stability, providing the possibility for monitoring CH3NO2 in complex real samples.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Direct electrochemistry; Electrochemical biosensor; Electrochemically-reduced graphene oxide; Graphene-chitosan/hemoglobin nanocomposite; Nitromethane

Mesh:

Substances:

Year:  2016        PMID: 26800205     DOI: 10.1016/j.bios.2016.01.028

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Voltammetric determination of organophosphorus pesticides using a hairpin aptamer immobilized in a graphene oxide-chitosan composite.

Authors:  Jiayun Fu; Yao Yao; Xingshuang An; Guangxian Wang; Yemin Guo; Xia Sun; Falan Li
Journal:  Mikrochim Acta       Date:  2019-12-09       Impact factor: 5.833

2.  Electrospun Chitosan-Gelatin Biopolymer Composite Nanofibers for Horseradish Peroxidase Immobilization in a Hydrogen Peroxide Biosensor.

Authors:  Siriwan Teepoo; Phanphruk Dawan; Naris Barnthip
Journal:  Biosensors (Basel)       Date:  2017-10-15

3.  Rationally designed naphthyl substituted amine functionalized ionic liquid platform for covalent immobilization and direct electrochemistry of hemoglobin.

Authors:  K Theyagarajan; Duraisamy Saravanakumar; Sellappan Senthilkumar; Kathavarayan Thenmozhi
Journal:  Sci Rep       Date:  2019-07-18       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.