Literature DB >> 26799982

On-line two-dimensional capillary electrophoresis with mass spectrometric detection using a fully electric isolated mechanical valve.

Felix J Kohl1, Cristina Montealegre1, Christian Neusüß1.   

Abstract

CE is becoming more and more important in many fields of bioanalytical chemistry. Besides optical detection, hyphenation to ESI-MS detection is increasingly applied for sensitive identification purposes. Unfortunately, many CE techniques and methods established in research and industry are not compatible to ESI-MS since essential components of the background electrolyte interfere in ES ionization. In order to identify unknown peaks in established CE methods, here, a heart-cut 2D-CE separation system is introduced using a fully isolated mechanical valve with an internal loop of only 20 nL. In this system, the sample is separated using potentially any non-ESI compatible method in the first separation dimension. Subsequently, the portion of interest is cut by the internal sample loop of the valve and reintroduced to the second dimension where the interfering compounds are removed, followed by ESI-MS detection. When comparing the separation efficiency of the system with the valve to a system using a continuous capillary only a slight increase in peak width is observed. Ultraviolet/visible detection is integrated in the first dimension for switching time determination, enabling reproducible cutting of peaks of interest. The feasibility of the system is successfully demonstrated by a 2D analysis of a BSA tryptic digest sample using a nonvolatile (phosphate based) background electrolyte in the first dimension.
© 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Interface; Mass-spectrometry; Two-dimensional capillary electrophoresis

Mesh:

Substances:

Year:  2016        PMID: 26799982     DOI: 10.1002/elps.201500579

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  3 in total

1.  Capillary Electrophoresis: Trends and Recent Advances.

Authors:  Robert L C Voeten; Iro K Ventouri; Rob Haselberg; Govert W Somsen
Journal:  Anal Chem       Date:  2018-01-18       Impact factor: 6.986

2.  Impact of linker-drug on ion exchange chromatography separation of antibody-drug conjugates.

Authors:  Zhaorui Zhang; Shiyue Zhou; Linjie Han; Qunying Zhang; Wayne A Pritts
Journal:  MAbs       Date:  2019-06-25       Impact factor: 5.857

3.  Two-Dimensional Capillary Electrophoresis with On-Line Sample Preparation and Cyclodextrin Separation Environment for Direct Determination of Serotonin in Human Urine.

Authors:  Juraj Piešťanský; Katarína Maráková; Peter Mikuš
Journal:  Molecules       Date:  2017-10-07       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.