Literature DB >> 26797677

Longitudinal Changes and Interobserver Variability of Systolic Myocardial Deformation Values in a Prospective Cohort of Healthy Fetuses across Gestation and after Delivery.

Shiraz Arif Maskatia1, Ricardo H Pignatelli2, Nancy A Ayres2, Carolyn A Altman2, Haleh Sangi-Haghpeykar3, Wesley Lee3.   

Abstract

BACKGROUND: Normative data for fetal myocardial deformation values have not been comprehensively described in a longitudinal cohort. The effect of gestational age on these values and on interobserver variability require further investigation.
METHODS: Sixty gravid women were prospectively enrolled before 20 weeks' gestation. The following measures were obtained by two blinded observers at five time points across gestation and also at 4 to 8 weeks' postnatal age: global circumferential strain and strain rate, global longitudinal left ventricular strain and strain rate, global longitudinal right ventricular strain and strain rate, and left and right ventricular myocardial performance indices. Optimal myocardial visualization and frame rate (≥100 frames/sec) were ensured.
RESULTS: For gestational age groups ≥24 weeks, intraclass correlation coefficients between observers were >0.70 for all measures and >0.85 for the majority of measures of myocardial deformation. At 20 to 21 weeks' gestation, intraclass correlation coefficients were 0.35 to 0.52 for longitudinal measures and 0.74 to 0.82 for circumferential measures. Myocardial performance index intraclass correlation coefficients were <0.80 at all time points and <0.70 for most time points. Global longitudinal left ventricular strain and global circumferential strain values remained stable across gestational age groups. Global longitudinal right ventricular strain values remained stable across gestation and increased after birth. Global circumferential strain rate, global longitudinal left ventricular strain rate, and global longitudinal right ventricular strain rate decreased from 20 to 21 weeks' gestation to the remainder of gestation and then remained stable until delivery. Upon delivery, global circumferential strain rate and global longitudinal left ventricular strain rate decreased, and global longitudinal right ventricular strain rate increased.
CONCLUSIONS: Interobserver variability of fetal strain and strain rate measured at ≥24 weeks' gestation was lower in comparison with values obtained at 20 to 21 weeks' gestation and lower in comparison with left ventricular and right ventricular myocardial performance indices using the described protocol. Gestational changes in fetal myocardial deformation values likely reflect changes in preload and/or afterload on the fetal heart.
Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cardiac function; Fetal echocardiography; Myocardial deformation; Myocardial performance index; Normative values; Pediatric; Strain; Strain rate

Mesh:

Year:  2016        PMID: 26797677     DOI: 10.1016/j.echo.2015.12.003

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

Review 1.  Controversies in the identification and management of acute pulmonary hypertension in preterm neonates.

Authors:  Regan E Giesinger; Kiran More; Jodie Odame; Amish Jain; Robert P Jankov; Patrick J McNamara
Journal:  Pediatr Res       Date:  2017-10-04       Impact factor: 3.756

2.  Fetal regional myocardial strain rate in the membranous ventricular septum: changes with gestational age and the left ventricular mass and predictive value for a complete membranous ventricular septum (without defect).

Authors:  Li-Juan Zhang; Ke-Qi Chen; Yun-Yan Shi; Xiao-Zhi Zheng
Journal:  Int J Cardiovasc Imaging       Date:  2018-04-17       Impact factor: 2.357

3.  Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.

Authors:  Laura Nogué; Olga Gómez; Nora Izquierdo; Cristina Mula; Narcís Masoller; Josep M Martínez; Eduard Gratacós; Greggory Devore; Fàtima Crispi; Mar Bennasar
Journal:  J Clin Med       Date:  2022-03-04       Impact factor: 4.241

Review 4.  Deformation imaging and rotational mechanics in neonates: a guide to image acquisition, measurement, interpretation, and reference values.

Authors:  Afif El-Khuffash; Ulf Schubert; Philip T Levy; Eirik Nestaas; Willem P de Boode
Journal:  Pediatr Res       Date:  2018-07       Impact factor: 3.756

5.  Normal fetal cardiac deformation values in pregnancy; a prospective cohort study protocol.

Authors:  Noortje H M van Oostrum; S Guid Oei; Judith O E H van Laar
Journal:  BMC Pregnancy Childbirth       Date:  2019-12-27       Impact factor: 3.007

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.