Literature DB >> 26796312

Double-Organ Bias in Published Randomized Controlled Trials of Glaucoma.

Fehim Esen1, Mehmet Köstek, Ahmed S Emekli, Muhsin Eraslan.   

Abstract

PURPOSE: Most of the statistical tests used in significance testing are based on the assumption that each data entry is independent from other entries, however, we observe that in many articles researchers include data from 2 eyes as independent variables while performing these statistical tests. The aim of this study was to formally survey the prevalence of the above-mentioned "double-organ bias" in randomized controlled trials (RCT) of glaucoma.
MATERIALS AND METHODS: We did a PubMed search with the terms "glaucoma" and limitations "Humans" and "Randomized Controlled Trials" in 15 highest-impact-factor ophthalmology journals between November 2002 and November 2012. We only included RCTs published as an original article, where the aim was treating glaucoma. Two independent observers (M.K. and A.S.E.) read through each article and classified the articles according to treatment modality (medical, laser, or surgical) and presence of double-organ bias.
RESULTS: The PubMed search yielded 270 articles. A total of 130 articles qualified for the survey. Eighty-five of the RCTs were medical studies, 11 were laser studies, and 34 studies evaluated the outcome of a surgical procedure. In 17 of the 130 articles (13.1%), double-organ bias was found. Prevalence of the double-organ bias was not significantly different between medical (12.9%), laser (14.7%), and surgical (9.1%) studies.
CONCLUSION: Double-organ bias was observed around 13.1% of the published RCTs, leading to inaccurate statistical testing.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26796312     DOI: 10.1097/IJG.0000000000000369

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  7 in total

1.  Choroidal thickness changes stratified by outcome in real-world treatment of diabetic macular edema.

Authors:  António Campos; Elisa J Campos; Anália do Carmo; Miguel Patrício; João P Castro de Sousa; António Francisco Ambrósio; Rufino Silva
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-07-23       Impact factor: 3.117

2.  Clinical outcome and endothelial loss following prepupillary and retropupillary implantation of iris claw intraocular lenses.

Authors:  Ebubekir Durmus; Fehim Esen; Melda Yenerel; Huseyin Sanisoglu; Halit Oguz
Journal:  Int Ophthalmol       Date:  2021-07-29       Impact factor: 2.031

3.  Refractive outcome of trocar-assisted sutureless scleral fixation with 3-piece intraocular lenses.

Authors:  Veysel Aykut; Fehim Esen; Fatma Sali; Halit Oguz
Journal:  Int Ophthalmol       Date:  2021-04-07       Impact factor: 2.031

4.  Analysis of Clinical Factors Associated with Retinal Morphological Changes in Patients with Primary Sjögren's Syndrome.

Authors:  Jee Myung Yang; Mi Sun Sung; Yong Sok Ji; Hwan Heo; Sang Woo Park
Journal:  PLoS One       Date:  2016-06-21       Impact factor: 3.240

5.  Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects.

Authors:  Seung Pil Bang; Chong Eun Lee; Yu Cheol Kim
Journal:  BMC Ophthalmol       Date:  2017-11-02       Impact factor: 2.209

6.  Combined Intracapsular Lens Removal and Scleral Fixation of Intraocular Lenses Through the Same Scleral Tunnel in Cases with Severely Dislocated Lenses.

Authors:  Selim Genç; Amber Şenel Kükner; Özum Yücel; Sariye Taşkoparan; Fehim Esen
Journal:  Beyoglu Eye J       Date:  2020-12-28

7.  Evaluation of markers of outcome in real-world treatment of diabetic macular edema.

Authors:  António Campos; Elisa J Campos; Anália do Carmo; Francisco Caramelo; João Martins; João P Sousa; António Francisco Ambrósio; Rufino Silva
Journal:  Eye Vis (Lond)       Date:  2018-10-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.